INOmax DS ir INOblender Pre-Use Procedure Rev -02

Pre-Use Procedure

2 Pages

Pre-Use Pre-UseProcedure Procedur A. Initial Connections  E. Perform backup delivery test  1. Check white plastic tip on regulator  1. Turn backup Delivery ON  2. Connect high pressure regulator  2. V  erify “backup ON” alarm activates  B. Perform high pressure leak test Note: Make sure INOmax DS backup and INOblender are OFF ®  1. Open/Close INOmax  cylinder valve  2. Wait 30 seconds and ensure no pressure drop  C. Perform low range calibration (second menu level) Note: Once the calibration is completed (bars turn green) press the menu button twice to return to the main screen  D. Perform purge  3. Verify values INOmax Dose = 14-26 ppm NO2  <1.0 ppm  4. Turn backup delivery OFF  F. Complete INOmax DS Performance Test 1. Ensure oxygen Table 1 flow of 10 L/min Acceptable INOmax 2. Set INOmax Value dose to 40ppm 3. Verify values in Acceptable NO2 Value Table 1 4. Turn the INOmax FiO 		 2 dose to zero  35-45 ppm <1.5 ppm 95% ±3%  G. Perform INOblender Test Note: Ensure INOblender inlet hose is connected to the back of the INOmax DS and the quickconnect cover is in place (see inset)  1. O2 Flowmeter 2. O2 Tubing 3. 15 M x 4.5 mm Adapter 4. 22 M / 15 F x 22 M / 15 F Adapter 5. Injector Module 6. 300 mm of 22 mm hose 7. Gas Sample Tee 8. Patient Gas Sample Line 9. NO/N2 Injector Tube 10. Injector Module Electrical Cable  1. Remove the Pre-Use set-up oxygen tubing from the oxygen flowmeter and connect it to the front of the INOblender 2. Remove the Injector Module from the Pre-Use Set-up. On the INOblender, set INOmax dose to 40 ppm and O2 flow to 10 L/min 40 ppm  10 L/min  1. Ensure cylinder valve is closed 2. Connect to wall or cylinder oxygen 3. Set O2 Flowmeter to 10 L/min 4. Set INOmax dose to 40 ppm 5. Purge is complete when “Low NO/N2 Pressure” alarm activates 6. Open cylinder valve 7. Turn INOmax dose to zero  3. Verify values on the INOmax DS Acceptable INOmax Value  32 - 48 ppm  4. Turn the dose and flow to zero and remove the Pre-Use set-up from the INOblender The INOmax DS is now ready to connect to the patient Warning: If not starting therapy within 10 minutes, depressurize the INOmax regulator  End of Pre-Use Procedure WARNING: This reference card is not a substitute for the INOmax DS and INOblender Operation and Maintenance manuals. Refer to these manuals for all applicable cautions and warnings.
File Type: PDF
File Size: 350 KB
File Name: inomax_ds_ir__inoblender_pre-use_procedure___rev_-0.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions