Guide

2 Pages

®  How To Determine What Can Be Sterilized In The STERRAD 200 Sterilizer  1  Is The Reprocessable Medical Device Made Of The Following Materials?**  ** This list of materials does not apply to trays and containers or other packaging materials. Please refer to the STERRAD® 200 User’s Guide for information on appropriate packaging materials for use in the STERRAD System.  - Aluminum - Brass  ®  - KRATON Polymers  - Polyetherimide (ULTEM Polymers)  - Polyurethane  - Neoprene  - Polymethyl methacrylate (PMMA)  - Polyvinyl chloride (PVC)  TM  ®  No/Don’t Know  - Delrin acetal resin (polyacetal)  - Non-mated Nylon (polyamide)  - Polyphenylene sulfone (Radel )  - Silicone elastomers  - Ethylvinyl acetate (EVA)  - Polycarbonate  - Polypropylene  - Stainless steel  - Glass  - Polyethylene  - Polystyrene  - Teflon® (polytetrafluoroethylene)  ®  ®  May have limited life after repeated sterilization. ® ® ® Delrin , Nylon , and Teflon are registered trademarks of the DuPont Corporation. KRATON™ Polymers is a trademark of KRATON Polymers U.S. L.L.C.  Please call the device manufacturer for information on how to properly sterilize this device.  - Titanium ULTEM® Polymers is a registered trademark of the GE Company. Contact ASP or the device manufacturer to determine the compatibility of any device manufactured from PMMA.  Yes  2  Does The Reprocessable Medical Device Have A Lumen?  No  Proceed with Processing.  Yes  3  ®  Is The Lumen Made Of Stainless Steel, Or Teflon ?  No/Don’t Know  Please call the device manufacturer for information on how to properly sterilize this device.  Yes  4  Proceed With Processing If The Lumen Conforms To The Dimensions Listed Below __ Teflon /Polyethylene Lumens  Stainless Steel Lumen Inside Diameter  Length  1 mm or larger  125 mm or shorter*  2 mm or larger  250 mm or shorter*  3 mm or larger  400 mm or shorter  Inside Diameter 6 mm or larger  1 mm (0.039 inches) 2 mm (0.078 inches) 3 mm (0.118 inches)  Length 310 mm or shorter  4 mm (0.157 inches)  * Validation testing for this lumen size was conducted using a maximum of 12 lumens per load. Your loads should not exceed the maximum number of lumens validated by this testing.  0 mm  Inside Lumen Diameters  ®  125 mm  5 mm (0.196 inches)  If the lumens do not conform to these dimensions, please call the device manufacturer for information on how to properly sterilize these devices. Lumens not conforming to these dimensions should not be processed in the STERRAD 200 Sterilizer.  200 mm  Measurements are approximate and are for reference only.  250 mm  6 mm (0.236 inches)  310 mm  Lumen Lengths  More Information More Information  400 mm
File Type: PDF
File Size: 53.6 KB
File Name: st_200_lumen_chart_.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions