LABORIE
LABORIE UDS System Installation Guide for Windows 7 OS Ver 18 October 2014
Installation Guide
190 Pages
Preview
Page 1
System Installation Guide for LABORIE UDS Systems with Windows 7® OS
LABORIE
LABORIE OFFICES: USA 400 Avenue D, Suite 10 Williston, Vermont, USA 05495 Sales/Marketing: 802.857.1300 Customer Service: 800.522.6743 Technical Support: 800.333.1039 Fax: 802.878.1122 [email protected]
CANADA 2101 Boul. Lapinière Brossard, Québec, Canada J4W 1L7 Montreal: 450.671.5901 Customer Service: 888.522.6743 Technical Support: 800.333.1039 Fax: 450.671.7182 [email protected]
EUROPE Lumonics House, Valley Drive Rugby, Warwickshire CV21 1TQ UK Tel.: +44.01788.547888 Fax: +44.01788.536434 [email protected]
INTERNATIONAL 6415 Northwest Dr., Unit 10 Mississauga, Ontario, Canada L4V 1X1 Customer Service: 905.612.1170 Fax: 905.612.9731 [email protected]
www.laborie.com
UDS120, GOBY, Urostym, EVOX AquaVu, and i-LIST are trademarks of LABORIE Medical Technologies Canada ULC. Windows, Microsoft Office, the Start Button, and Internet Explorer are registered trademarks of Microsoft Corp. Bluetooth is a registered trademark of Bluetooth SIG, Inc. HP is a registered trademark of the Hewlett Packard Company. StarTech products are trademarks of StarTech.com. Adobe Acrobat and Adobe Reader are registered trademarks of Adobe Systems Incorporated in the U.S. and other countries. Norton AntiVirus is a trademark of Symantec Corporation or its affiliates in the U.S. and other countries. PIXMA is a trademark of Canon Inc. SeeMore is a trademark of Interson Corp. TECRA is a trademark of Toshiba Corporation. All other names are trademarks of their respective owners. © Copyright 2014 by LABORIE. All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior written permission of LABORIE.
Document Number: UDS120-UM05 Version Number: 18 Release Date: October 23, 2014 Issued By: R.A.
ABOUT THIS INSTALLATION GUIDE This guide, divided in four parts, describes how to set up and install Laborie software and/or accessories on your computer with the Windows® 7 OS.
IMPORTANT NOTES BEFORE START OF INSTALLATION
NOTE 1: Plug only the power supply into the laptop or PC. Do not connect any cables or devices that would enable an internet connection until instructed to do so during installation. NOTE 2: It is recommended to have Windows 7 OS 64-bit version installed.
INSTALLATION PROCESS
Part 1
System Setup
Starting on page 1
Part 2
Driver and Peripherals Installation
Starting on page 71
Part 3
Laborie Software Installation
Starting on page 115
Part 4
System Finalization
Starting on page 179 Follow the sections in this guide in the order as outlined for proper installation. If you encounter any problems during installation, please contact LABORIE Technical Support at 1-800-333-1039. For troubleshooting information see page 182.
REVISION HISTORY Manual Version
Date
Note
18
October 23, 2014
Updated installation for recommended Nitro PDF Pro V10 (see page 56)
17 16
May 5, 2014 March 14, 2014
15 14
December 5, 2013 August 20, 2013
13
August 12, 2013
12
May 17, 2013
11
January 15, 2013
10
June 1, 2012
9.0
March 7, 2012
8.0
January 13, 2012
7.0
December 6, 2011
6.0
September 13, 2011
5.0 4.0
August 16, 2011 April 1, 2011
Updated display resolution settings for PC configuration (see page 8) Updated minimum requirements for installation; Updated PC configuration instructions; Added configuration instructions for recommended Toshiba Tecra Z50 laptop; Added Grid Connect USB serial adapter installation instructions; Updated EVOX installation section; Updated i-LIST Office Reporter section to include patch installation instructions; Removed COM Port Standardization from Appendix Updated i-LIST Installation instructions (see page 157) Updated StarTech USB to Serial installation instructions to add PER381; Updated laptop connection diagram for Urostym installation; Added new COM port standardization information Removed previous USB to Serial adapter information and replaced with new StarTech USB to Serial installation instructions; Added note for StarTech serial adapter use with installation of UDS120 software with a wired connection; Updated Urostym installation instructions to reference new StarTech USB to Serial adapter; Removed COM port standardization information Removed configuration for Toshiba Tecra A11 laptop and DELL T3500 PC models; Updated minimum requirements; Updated configuration information for DELL E6530 laptops; Updated configuration information for DELL Precision T3600 PC; Updated PDF installation instructions; Updated Antivirus configuration information; Updated UDS120 software installation instructions; Updated EVOX installation instructions; Updated iLIST Office Reporter installation instructions Updated minimum requirements; Added configuration information for DELL E6530 laptops; Added configuration information for DELL Precision T3600 PC; Added Antivirus configuration information for DELL E6530 laptop and DELL Precision T3600 PC; Added HP OfficeJet 6100 Printer information; Updated COM port settings Added installation information to enable use of Urostym system with Urocap IV standalone (see page 175) Added compatibility of UDS Goby software with HASP key driver installation; Added reminder to plug the HASP key into all USB ports of PC once Goby software installed; added HASP key pop-up message that appears with a new install; also updated Device Manager screenshots; Added compatibility of UDS Goby software with current version of i-LIST Office reporter software Updated minimum requirements for installation; Updated service pack information and Windows OS updates setup; Added step for increasing virtual memory (for desktop PCs only); Added note at end of each type of UDS120 installation for UDS-94 hardware with a V1.05 board set; Added software patch installation instructions for each type of installation; Added note before installation of SeeMore™ ultrasound probe driver Updated minimum requirements for installation; Added ATI FirePro Video Driver installation instructions; Added HASP Key Driver installation instructions; Added installation instructions for NuWav ultrasound probe with UDS120 software(optional feature); Updated UDS120 installation instructions and removed patch installation instructions; Added TETRA installation note; Added Urocap IV standalone installation; Added EVOX installation instructions; Updated installation instructions for iLIST Reporter V1.2.2.9; Added SeeMore™ ultrasound probe driver installation instructions; Added VISER installation instructions; Added Turn off automatic updates step in System Finalization section; Added COM Port Standardization Added printer driver installation instructions for the Canon PIXMA™ iP100 series wireless printer Added software patch installation instructions for UDS120 V12.0.3 software Added AquaVu software installation instructions
Manual Version
Date
Note
3.0
February 11, 2011
2.0
December 10, 2010 Updated for UDS120 V12 release October 1, 2010
Updated Minimum Specifications; Added configuration information for laptop and PC models recommended by LABORIE; Added step to Bluetooth configuration; Updated Urostym connection diagrams Updated Minimum Specifications; Added placement of Bluetooth Devices function; Updated UDS120 installation instructions for version 12; Added troubleshooting information Creation of first version of system configuration guide.
1.0
IMPORTANT NOTE! Installation and configuration must first be performed under Administrator mode. The creation of additional administrator and/or user groups will require a repeat of the settings outlined in this guide.
LABORIE System Installation Guide for Windows 7 OS
Part 1: System Setup - required for all installations This part outlines how to set up the computer before installing any drivers and/or Laborie software. This part must be followed point-by-point. Once the sections in this part of the guide are complete, you can then proceed to the installation of drivers and/or the Laborie software. Minimum Requirements for Software Installation (see page 2)
Configure the Embedtek PC (see page 3) Configure the Toshiba TECRA™ Z50 Laptop (see page 14) Configure the DELL E6530 Laptop (see page 32)
Install any other software such as MS Office, Adobe Acrobat/Reader, or NitroPDF® Professional (see page 47)
Page 1
LABORIE System Installation Guide for Windows 7 OS
Minimum Requirements for Software Installation
Operating System: Microsoft® Windows® 7 64-bit Service Pack 1 AntiVirus software (Microsoft® Security Essentials recommended)
EmbedTek Industrial PC (Base System):
Intel Q67 Chipset-based platform Intel Core i3 3220S processor (55W) (embedded) o 3.3 GHz, 2 cores, 4 threads, 3MB cache 4 GB DDR-3 Dual Channel System Memory o Upgradeable up to 32GB Dual GbE Wireless Networking (via USB) 500GB 3.5” Hard Drive Dimensions: 3”H x 11.5”W x 11.5”D (black) Internal CD/DVD RW I/O o 7.1 CH Audio, 1 x RS-232 serial port, 6 x USB 2.0, 1 x VGA port, 2 x HDMI 1.4 ports Windows 7
EmbedTek Industrial PC (High End): Same Configuration as Base System plus:
I7 3770T (45W) (Embedded) o 2.5 GHz (3.7 GHz Max) , 4 cores, 8 threads, 8MB cache RAID 1 (2x 2.5” 500GB HD’s in place of 3.5”HD) 8 GB RAM
Toshiba Tecra Z50 for all systems with laptop:
Intel® Core™ i5 Processor, 2.4 GHz or higher Windows 7, 64-bit RAM: 4GB or higher Hard disk: 320GB or higher 15.6" display 1 built-in COM port USB 2.0 ports: Minimum 4 Bluetooth 4.0 (867Mbps)
DELL E6530 for all systems with laptop:
Intel Core i5-4300M Processor 2.5GHz or higher RAM: 4.0GB, DDR3-1600MHz SDRAM or higher Hard drive: 320GB, 7200rpm or higher 8X DVD+/-RW drive or higher 15.6” display USB 2.0/3.0 ports: Minimum 4 Bluetooth 4.0 Windows 7, 64-bit Intel® HD graphics 4600
Page 2
LABORIE System Installation Guide for Windows 7 OS
Configure the Embedtek PC Disable User Access Control (UAC) Click Start > Control Panel. In the Control Panel, select Large icons in the upper-right of the window.
Scroll down the window and click User Accounts. Click the Change User Account Control settings option and set it to the lowest level possible of Never notify.
Click OK and then exit the Control Panel.
Set up MSMQ and .NET Framework 1. Click Start > Control Panel > Program and Features. 2. Click on ‘Turn Windows features on or off’ to open the Windows Features window. 3. Under this window, select all components under ‘Microsoft .NET Framework 3.x’. Under ‘Microsoft Message Queue (MSMQ) Server’ select only ‘MSMQ Triggers’ as shown in the following image:
Page 3
LABORIE System Installation Guide for Windows 7 OS
4. Select “Internet Information Services”, under “Internet Information Services” click on “IIS 6 Management Console” and then click on “IIS Metabase and IIS 6 configuration compatibility” as shown in the next screenshot.
5. Register ASP.NET on IIS by following steps. a. Open command window, and type: For 32-BIT OS “cd C:WindowsMicrosoft.NETFramework64v2.0.50727” For 64-BIT OS “cd C:WindowsMicrosoft.NETFramework64v2.0.50727” for 64 bit OS, and press Enter key. Page 4
LABORIE System Installation Guide for Windows 7 OS
b. Type the command “aspnet_regiis -i” and press Enter key, and wait.
6. Enable 32-Bit Applications from IIS Manager for 64 bit Operating System. a. Click Start icon and enter “iis” in ‘Search programs and files’, and select Internet Information Services (IIS) Manger from the list as shown next screenshot.
Page 5
LABORIE System Installation Guide for Windows 7 OS
b. The Internet Information Services (IIS) Manger window will be opened as shown below.
c. Open Advanced Settings window by select Application Pools -> DefaultAppPool, and select ‘Advanced Settings…’ on the right pane. Select True on the Enable 32-Bit Applications option.
Click OK and continue with the next step.
Page 6
LABORIE System Installation Guide for Windows 7 OS
Set up Driver Update Properties
Click Start > Control Panel > System and click the Advanced system settings heading on the left side of the window.
In the resulting System Properties window click the Hardware tab and then click the Device Installation Settings button.
Page 7
LABORIE System Installation Guide for Windows 7 OS
Copy the selections as shown here:
Click the Save Changes button and continue with the next step.
NOTE: Plug in the network cable to connect to the internet as it is now required for the following steps.
Regional and Language Options Setup Procedure See instructions on page 37.
Verify the Display Resolution For single monitor setup:
Click Start > Control Panel > Display. Verify the resolution of the monitor is set to 1440 x 900.
For dual monitor setup:
Plug in the primary monitor first; then plug in the secondary monitor. Continue with the next step.
Page 8
LABORIE System Installation Guide for Windows 7 OS
Configure the Universal Serial Bus Controller Settings Click Start > Control Panel. From the Control Panel window click Device Manager. From the list locate and double-click on the entry for ‘Universal Serial Bus Controllers’. Double-click the first listing of ‘USB Root Hub’ to open the USB Root Hub Properties window. In the Power Management tab, confirm that no check marks are present beside the ‘Allow the computer to turn off this device to save power’ setting. Repeat for all ‘USB Root Hub’ entries listed. Click OK. Double-click the first listing of ‘Generic USB Hub’ (if visible) to open the Generic USB Hub Properties window. In the Power Management tab, confirm that no check marks are present beside the ‘Allow the computer to turn off this device to save power’ setting. Repeat for all ‘Generic USB Hub’ entries listed. Click OK.
Click Apply and then click OK. Close all open windows and continue with the next step.
Configure Power Options Click on Start > Control Panel and click Power Options. In the Select a power plan window, click on Choose what the power button does located on the topleft side of the window. Copy the settings illustrated in the following image:
Click the Save changes button. In the Select a power plan window, select the Dell option if not already selected. Click the Change plan settings heading to open the Change Settings window. Copy the settings as shown in the following image:
Page 9
LABORIE System Installation Guide for Windows 7 OS
Dell settings
Click the Change advanced power settings heading and make adjustments to each item under the Advanced settings tab. Copy the settings for each item as shown in the following images:
Hard disk settings
Page 10
LABORIE System Installation Guide for Windows 7 OS
Desktop background settings settings
Wireless Adapter Settings settings
Sleep settings
USB settings settings
Page 11
LABORIE System Installation Guide for Windows 7 OS
Power buttons and lid settings
PCI Express settings
Processor power management settings
Display settings
Page 12
LABORIE System Installation Guide for Windows 7 OS
Multimedia settings settings
Click Apply, then click OK, and then click the Save changes button. Close all open windows. Continue with the installation of any other software (see page 47).
Remove SQL Server 2005 Application Go to Control Panel > Program and Features and verify that the Microsoft SQL Server 2005 Compact Edition [ENU] application is not installed. If it is, un-install the program and then restart the computer. Continue by installing any other third-party software such as Adobe Reader, PDF creators. etc… then go to Part 2.
Page 13
LABORIE System Installation Guide for Windows 7 OS
Configure the Toshiba TECRA™ Z50 Laptop Disable User Access Control Click Start > Control Panel. In the Control Panel, select Large icons in the upper-right of the window.
Scroll down the window and click User Accounts. Click the Change User Account Control settings option and set it to the lowest level possible of Never notify.
Click OK and then exit the Control Panel.
Page 14