Laerdal

Laerdal Manikin Simulators

SimMan 3G DFU Update Blood and Fluid System Rev A

Update

2 Pages

SimMan 3G  DFU Update - Blood and Fluid System  Terms uses in this document BFU – Blood Fill Unit FFU – Fluid Fill Unit EFU – External Fill Unit (Generic, non specific term for BFU and FFU) BI – Blood Inlet (on manikin) FI – Fluid Inlet (on manikin)  3 - Connect the tube from the FFU to the FI on the manikin panel. 4 - Pressurize the FFU by pumping the handle 15-20 times. 5 - Press the thumb lever until locked in place to release liquid into the manikin.  Blood and Fluid System In the manikin there are two internal reservoirs, one for blood and one for fluids/secretions. SimMan 3G is also supplied with two External Fill Units (EFU) - one Blood Fill Unit (BFU) for blood and one Fluid Fill Unit (FFU) for fluids /secretions.  SimMan 3G  SimMan 3G Fluid Fill Unit  Fluid Fill Unit  Preparing the Internal Reservoirs for fluid and blood filling Note! Make sure the manikin power is turned on and the 		 condensation valve, on the back of manikin’s right thigh, is closed /OFF Internal Fluid Reservoir 1 - Loosen the cap of the FFU to let air in, (do not remove). 2 - Connect the tube from the FFU to the Fluid inlet (FI) on the manikin panel. Air / CO2 Inlet  Fluid Inlet  6 - Wait approximately 2 minutes or until 200ml of the liquid has transferred to the manikin. Refer to the scale on the outside of the FFU. If the fluid rate slows down, pump the handle additional times. 7 - When the manikin’s reservoir is full (200ml), unplug the tube from the FI. 8 - Close /OFF the condensation valve. Blood Inlet  Blood Outlet  SimMan 3G Fluid Fill Unit  Filling the internal reservoirs with blood 3 - Press the thumb lever on the FFU. When no more fluid/air runs out into the FFU release the thumb lever. 4 - Disconnect the tube from FI. Internal Blood Reservoir 1 - Loosen the cap of the BFU to let air in, (do not remove). 2 - Connect the tube from the BFU to the blood inlet (BI) on the manikin panel. 3 - Press the thumb lever on the BFU (when no more blood/air runs out into the BFU, release the thumb lever) 4 - Disconnect the tube from BI. SimMan 3G Fluid Fill Unit  Filling the internal reservoirs with fluid 1 - Fill the FFU with 900ml of liquid (See Section Mixing of Blood and Fluid) and tighten the cap. 2 - Open/ON the condensation valve, releasing the static pressure in the manikin’s tank.  1 - Fill the BFU with 900ml of blood (See Section Mixing of Blood and Fluid) and tighten the cap. 2 - Open/ON the condensation valve, releasing the static pressure in the manikin’s tank. 3 - Connect the tube from the BFU to the BI on the manikin panel. 4 - Pressurize the BFU by pumping the handle 15-20 times. 5 - Press the thumb lever until locked in place to release blood into the manikin. 6 - Wait approximately 2 minutes or until 400ml of the blood has transferred to the manikin. Refer to the scale on the outside of the BFU. If the fluid (blood) rate slows down, pump the handle additional times. 7 - When the manikin’s reservoir is full (400ml), unplug the tube from the BI 8 - Close/OFF the condensation valve. Topping up the internal reservoirs of the manikin between sessions/scenarios The manikin can be topped up with fluid/blood between training sessions. To do this, follow the instructions for filling above. Avoid this method during sessions/scenarios as it will disturb the air functions of the manikin.
File Type: PDF
File Size: 1.75 MB
File Name: simman_3g_dfu_update_blood_and_fluid_system_rev_a.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions