Lec Medical
Pharmacy Plus User Manual Rev 0.06 Aug 2022
User Manual
36 Pages
Preview
Page 1
USER MANUAL Pharmacy Plus - Laboratory Plus - Pharmacy Connect Operating Instructions 083870100 – Rev 0.06 - 15/08/22
www.lec-medical.co.uk
The Experts in Medical Refrigeration 0
Contents 1: Models ... 3 2: Safety Instructions ... 5 3: General Recommendations ... 6 4: Product Specifications ... 7 Flammable Material Storage Units FMS (Lab products only) ... 9 5: Product Details ... 10 5:1 Pharmacy Plus/Connect Refrigerators – UC and FS ... 10 5:2 Laboratory Plus Refrigerators – UC and FS ... 11 5:3 Laboratory Plus Freezers - UC and FS ... 12 5:4 Laboratory Plus Refrigerator/Freezer Combi – FS... 13 5:5 Pharmacy Plus Refrigerators – CT ... 14 6: Installation ... 15 Positioning and safely using the Refrigerator ... 15 Electrical Connections ... 16 7: Before Switching On ... 17 8: Operation... 18 8:1 IJ Controller Overview ... 18 8:2 IJ Controller Default Operating Displays ... 19 9: Basic Operations using the LEC Medical App ... 20 9:1 Download and install the LEC Medical App ... 20 9:2 Connecting to an appliance ... 20 9:3 App Home Page ... 21 9:6 Accessing Min/Max temperatures ... 21 9:5 Re-Setting Min/Max Temperatures using the APP ... 22 9:6 Re-Naming the Appliance ... 22 9:7 Changing the Set Point ... 23 9:8 Operating the internal light ... 23 9:9 Switching the appliance on and off ... 24 10: Advanced Operations using the LEC Medical App ... 25 11: Operations using the controller touch screen ... 26 11:1 Unlocking the controller ... 26 11:2 Viewing and re-Setting Min/Max Temperatures on the controller ... 26 11:2:1 Select air or load temperature ... 26 11:2:2 To View the max and min temperature ... 26 11:2:3 To reset max and min temperatures... 27 11:3 Changing the Set Point ... 28 11:4 Initiating manual defrost ... 29 12: Alarm and signal Status ... 30 12:1 Alarm Table ... 30 1
12:1 Display Signals ... 31 13: Trouble Shooting ... 32 14: Disposal of your refrigerator ... 34 15: Contact Information ... 35
2
1: Models
310 310 400
Pharmacy Connect
158
400
Pharmacy Plus - Neonatal
158
Range Vol L
SKU No 444411308
PPSR158BT-UK
444411311
PPSR158BT-EU
444411325
PPSR158BT-DWP-UK Boots
444411387
PPSR158BT-DWP
444411389
PPSR158BT-DLK
444411377
NSR158BT-UK
444411309
PPGR158BT-UK
444411310
PPGR158BT-LHH-UK
444411312
PPGR158BT-EU
444411388
PPGR158BT-DWP
444411390
PPGR158BT-DLK
444411313
PPSR310BT
444411394
PPSR310BT-DWP
444411391
PPSR310BT-DLK
444411314
PPGR310BT
444411315
PPGR310BT-LHH
444411393
PPGR310BT-DWP
444411392
PPGR310BT-DLK
444411317
PPSR400BT
444411398
PPSR400BT-DWP
444411396
PPSR400BT-DLK
444411316
PPGR400BT
444411318
PPGR400BT-LHH
444411397
PPGR400BT-DWP
444411395
PPGR400BT-DLK
444411319
PCSR158CT-UK
444411321
PCSR158CT-EU
444411323
PCSR158CT-DWP-UK
444411326
PCSR158CT-DLK-UK
444411320
PCGR158CT-UK
444411322
PCGR158CT-EU
444411324
PCGR158CT-DWP-UK
444411327
PCGR158CT-DLK-UK
444411328
PCSR310CT
444411330
PCSR310CT-DLK
444411332
PCSR310CT-DWP
444411329
PCGR310CT
444411331
PCGR310CT-DLK
444411333
PCGR310CT-DWP
444411335
PCSR400CT
444411337
PCSR400CT-DLK
444411339
PCSR400CT-DWP
444411334
PCGR400CT
444411336
PCGR400CT-DLK PCGR400CT-DWP
444411338 3
Model
Models cont. Model PPSR47BT-EU
444411306
PPGR47BT-UK
444411376
NSR47BT-UK
444411305
PPSR47BT-UK
444411307
PPSR47BT-EU
444411306
PPGR47BT-UK
SKU No 444411358
LSFSR158BT-UK
444411359
LSFSR158BT-EU
444411360
LSFSR310BT-UK
444411361
LSFSR310BT-UK-ATEX
444411364
LSFSR400BT
444411365
LSFSR400BT-ATEX
444411352
LSFSF98BT-UK
444411353
LSFSF98BT-EU
444411362
LSFSF242BT-UK
444411363
LSFSF242BT-UK-ATEX
444411366
LSFSF312BT
444411367
LSFSF312BT-ATEX
444411369
LSFSC280BT
444411370
LSFSC280BT-ATEX
98
Vol L 158
444411307
310
PPSR47BT-UK
400
444411305
242
47
SKU No
312
Laboratory Plus
Range
Vol L
280
Pharmacy Plus Neonatal
Range
Model
4
2: Safety Instructions In this manual, the following symbols and conventions are used: -
This symbol when used alone indicates important operating instructions which reduce the risk of injury or poor performance of the unit. WARNING: A situation which if not avoided, could result in serious injury or death. CAUTION: A situation which, if not avoided, may result in minor or moderate injury, impaired performance, or damage to the equipment. CAUTION: Before installing, using, or maintaining this product, please be sure to read this manual and product warning labels carefully. Failure to follow these instructions may cause this product to malfunction, which could result in injury or damage. WARNING: Potential danger of electric shock which, if not avoided, could result in serious injury or death. WARNING: These units are charged with hydrocarbon refrigerant. Only qualified service personnel should service these units. The snowflake symbol indicates extreme low temperatures and high risk of frostbite. Do not touch bare metal or samples with unprotected body parts. WARNING: This symbol indicates a need to use gloves during the indicated procedures. If performing decontamination procedures, use chemically resistant gloves. Use insulated gloves for handling samples to avoid potential frostbite.
5
3: General Recommendations Intended Use and Special Warning This equipment is tested in compliance with established regulations and then shipped ready for use. This equipment is intended for cold storage and is not to be used in the presence of explosive gases or mixtures and/or close to sources with high magnetic or electric fields/
WARNING: These units are not medical devices and have not been registered with a medical device regulatory body (e.g., MDD/MDR). These products have not been evaluated for the storage of samples for diagnostic use, nor for samples to be reintroduced into the body.
WARNING: Do not damage the refrigeration circuit WARNING: Do not use electrical equipment inside the storage unless they are of the type recommended by the manufacturer. WARNING: Keep ventilation openings, in the equipment enclosure or in the built-in structure, clear of obstruction. WARNING: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer
Energy Saving Tips This equipment uses energy efficient R600a refrigerant. To keep running costs as low as possible always: • Position the equipment away from heat sources. •
Make sure the air can circulate freely around the equipment, don’t block ventilation grid
•
Ensure that products being stored are below room temperature upon entry.
•
Make sure the door is opened as little as possible while in use and closed as quickly as possible to prevent unnecessary temperature fluctuations.
Important Information
R600a
The refrigerator contains environment-friendly, non-ozone depleting refrigerant R600a. As R600a is a flammable gas, it is important to avoid damage to the refrigeration circuit during transport and installation. If the refrigeration circuit is damaged, avoid using a naked flame in the vicinity of the refrigerator and connecting power to the refrigerator. Also make sure there is good ventilation in the room. If you are in doubt, please contact your supplier.
6
4: Product Specifications This range of LEC refrigerators and freezers have been designed and built with the intention of the product being used within pharmacies, hospitals, and laboratories. Please see below for specific product information. Pharmacy Plus and Neonatal Range Refrigerators SKU No
Model
444411305 PPSR47BT-UK 444411307 PPSR47BT-EU
Width (mm)
Inc Handle
Weight (Kg)
Rating (Amp)
Power (W)
Temperature Range
Ambient Temperature
Refrigerant
(mm)
565
475
445
17.5
0.60
70
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
445
17.5
0.60
70
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
565
475
444411306 PPGR47BT-UK
565
475
445
18.5
0.60
70
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411376 NSR47BT-UK
565
475
445
17.5
0.60
70
2⁰C to 4⁰C
25⁰C to 32⁰C
R600a
444411308 PPSR158BT-UK
850
595
660
33.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411311 PPSR158BT-EU
850
595
660
33.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411325 PPSR158BT-DWP-UK Boots 444411387 PPSR158BT-DWP
850
595
660
38.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
850
595
660
38.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
660
33.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
0.78
101
2⁰C to 4⁰C
25⁰C to 32⁰C
R600a
444411389 PPSR158BT-DLK
850
595
444411377 NSR158BT-UK
850
595
660
38.3
444411309 PPGR158BT-UK
850
595
645
36.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411310 PPGR158BT-LHH-UK
850
595
645
36.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411312 PPGR158BT-EU
850
595
645
36.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411388 PPGR158BT-DWP
850
595
645
39.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411390 PPGR158BT-DLK
850
595
645
36.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411313 PPSR310BT
1560
595
660
50.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411394 PPSR310BT-DWP
1560
595
660
58.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411391 PPSR310BT-DLK
1560
595
660
50.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411314 PPGR310BT
1560
595
645
60.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411315 PPGR310BT-LHH
1560
595
645
50.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411393 PPGR310BT-DWP
1560
595
645
68.6
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411392 PPGR310BT-DLK
1560
595
645
50.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411317 PPSR400BT
1925
595
660
61.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411398 PPSR400BT-DWP
1925
595
660
74.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411396 PPSR400BT-DLK
1925
595
660
61.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411316 PPGR400BT
1925
595
645
69.6
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411318 PPGR400BT-LHH
1925
595
645
61.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411397 PPGR400BT-DWP
1925
595
645
82.6
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
645
61.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411395 PPGR400BT-DLK
7
Depth
Height (mm)
1925
595
Product Specifications cont. Pharmacy Connect Range Refrigerators Depth
SKU No
Model
Height (mm)
Width (mm)
Inc Handle
Weight (Kg)
Rating (Amp)
Power (W)
Temperature Range
Ambient Temperature
Refrigerant
(mm)
444411319
PCSR158CT-UK
850
595
660
18.5
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411321
PCSR158CT-EU
850
595
660
18.5
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411323
PCSR158CT-DWP-UK
850
595
660
39.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411326
PCSR158CT-DLK-UK
850
595
660
18.5
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411320
PCGR158CT-UK
850
595
645
37.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411322
PCGR158CT-EU
850
595
645
37.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411324
PCGR158CT-DWP-UK
850
595
645
40.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411327
PCGR158CT-DLK-UK
850
595
645
37.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411328
PCSR310CT
1560
595
660
51.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411330
PCSR310CT-DLK
1560
595
660
51.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411332
PCSR310CT-DWP
1560
595
660
59.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411329
PCGR310CT
1560
595
645
61.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411331
PCGR310CT-DLK
1560
595
645
61.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411333
PCGR310CT-DWP
1560
595
645
69.6
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411335
PCSR400CT
1925
595
660
62.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411337
PCSR400CT-DLK
1925
595
660
62.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411339
PCSR400CT-DWP
1925
595
660
75.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411334
PCGR400CT
1925
595
645
70.6
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411336
PCGR400CT-DLK
1925
595
645
70.6
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
Laboratory Plus Refrigerators Depth
SKU No
Model
Height (mm)
Width (mm)
Inc Handle
Rating (Amp)
Power (W)
Temperature Range
Ambient Temperature
Refrigerant
(mm)
Weight (Kg)
444411358
LSFSR158BT-UK
850
595
660
17.9
0.78
101
2⁰C to 10⁰C
16⁰C to 32⁰C
R600a
444411359
LSFSR158BT-EU
850
595
660
17.9
0.78
101
2⁰C to 10⁰C
16⁰C to 32⁰C
R600a
444411360
LSFSR310BT-UK
1560
595
660
49.0
0.47
60
2⁰C to 10⁰C
16⁰C to 32⁰C
R600a
444411361
LSFSR310BT-UK-ATEX
1560
595
660
49.0
0.47
60
2⁰C to 10⁰C
16⁰C to 32⁰C
R600a
444411364
LSFSR400BT
1925
595
660
0.49
66
2⁰C to 10⁰C
16⁰C to 32⁰C
R600a
444411365
LSFSR400BT-ATEX
1925
595
660
66.0 66.0
0.49
66
2⁰C to 10⁰C
16⁰C to 32⁰C
R600a
Laboratory Plus Freezers Depth
SKU No
Model
Height (mm)
Width (mm)
Inc Handle
Weight (Kg)
Rating (Amp)
Power (W)
Temperature Range
Ambient Temperature
Refrigerant
(mm)
444411352
LSFSF98BT-UK
850
595
660
42.0
0.62
80
-18⁰C to -25⁰C
16⁰C to 32⁰C
R600a
444411353
LSFSF98BT-EU
850
595
660
42.0
0.62
80
-18⁰C to -25⁰C
16⁰C to 32⁰C
R600a
444411362
LSFSF242BT-UK
1560
595
660
65.0
0.86
88
-18⁰C to -25⁰C
16⁰C to 32⁰C
R600a
444411363
LSFSF242BT-UK-ATEX
1560
595
660
65.0
0.86
88
-18⁰C to -25⁰C
16⁰C to 32⁰C
R600a
444411366
LSFSF312BT
1925
595
660
84.1
1.35
130
-18⁰C to -25⁰C
16⁰C to 32⁰C
R600a
444411367
LSFSF312BT-ATEX
1925
595
660
84.1
1.35
130
-18⁰C to -25⁰C
16⁰C to 32⁰C
R600a
8
Product Specifications cont. Laboratory Plus Fridge/Freezer Combi Depth
SKU No
Model
Height (mm)
Width (mm)
Inc Handle
(mm)
Weight (Kg)
Rating (Amp)
Power (W)
444411352
LSFSF280BT-UK
TBC
595
660
TBC
TBC
TBC
444411353
LSFSF280BT-EU
TBC
595
660
TBC
TBC
TBC
Temperature Range
Fr +2⁰C to +10⁰C Fz -18⁰C to -25⁰C Fr +2⁰C to +10⁰C Fz -18⁰C to -25⁰C
Ambient Temperature
Refrigerant
16⁰C to 32⁰C
R600a
16⁰C to 32⁰C
R600a
Flammable Material Storage Units FMS (Lab products only) Conventional refrigerators are not suitable for storing flammable materials. Such units have components in their electrical and refrigeration systems that can trigger explosions of flammable air-vapor mixtures inside the unit. FMS refrigerators/freezers are designed for use in locations which are not classified as hazardous by the Authority Having Jurisdiction (AHJ). Under normal operating conditions, the build-up or presence of flammable vapours will not occur in the environment outside the unit. Flammable Materials Storage (FMS) refrigerators/freezers are designed for use in general laboratory locations. FMS units are NOT designed for use in Class I, Zone 0, or Zone1 applications, which require an Explosion-Proof Refrigerator/Freezer. FMS units are designed, evaluated and comply with the ATEX Directive 2014/34/EU Annex VIII. These units have an intrinsically safe (IS) barrier installed in the temperature probe circuit with no other internal electrical components that could trigger an explosion or fire of flammable materials inside the unit. The internal wall construction has been reviewed and is not a source for electrostatic build up due to the materials used in construction. The units bear the following ATEX marking.
These units are ideal for storing ethyl ether, acetone, alcohol, benzene, butane, gasoline, hexane, lacquer solvent, and naphtha along with many other potentially flammable materials. Refrigerators, Freezers and Fridge Freezers for use in potentially explosive atmospheres, the internal refrigeration chamber is classed as Zone 2, category 3 when the door is closed. The external parts of the refrigerator are classed as safe area and as such do not need to comply with requirements of the directive.
9
5: Product Details 5:1 Pharmacy Plus/Connect Refrigerators – UC and FS Details for Families 158L, 310L, 400L
1 2
3
1
Bluetooth enabled controller
2
Key lock or digital lock
3
Antimicrobial handle
4
Fixed wire shelf - qty 1
5
Wire Basket
6
Adjustable feet 2 at front
7
Door support foot not on 158L
8
Details Family Specific 8
Movable shelves - 158L qty 3
8
Movable shelves - 310L qty 4
8
Movable shelves - 400L qty 6
8
Fixed drawers - 158L qty 3 Details Range Specific
9
Drip tray - all ranges
10
Battery Pharmacy - Plus/Connect
11
Remote control unit - Connect
4
5
6 7
Compressor housing Pharmacy Essential
Compressor housing Pharmacy Plus
Compressor housing Pharmacy Connect
10
Product Details cont. 5:2 Laboratory Plus Refrigerators – UC and FS Details Families 158L, 310L, 400L
1 2
3
1
Bluetooth enabled controller
2
Key lock
3
Antimicrobial handle
4
Fixed wire shelf - qty 1
5
Wire Basket
6
Adjustable feet two at front
7
Door support foot not on 158L
8
Details Family Specific
10
4
8
Movable wire shelves - 158L qty 3
8
Movable wire shelves - 310L qty 4
8
Movable wire shelves - 400L qty 6
10
Door tray shallow – 158L qty 2
10
Door tray shallow – 310L qty 3
10
Door tray shallow – 400L qty 4
11
Door tray deep – 158L qty 1
11
Door tray deep – 310L qty 2 Door tray deep – 400L qty 3
11 11
Details Range Specific 9
5
6 7
Compressor housing Laboratory Plus
11
Drip tray - all ranges
Product Details cont. 5:3 Laboratory Plus Freezers - UC and FS Details Families 158L, 310L, 400L
1 2
3
1
Bluetooth enabled controller
2
Key lock
3
Antimicrobial handle
5
Freezer Tray Small
6
Adjustable feet 2 at front
7
Door support foot not on 98L Details Family Specific
4
4
Freezer Tray Large 98L – Qty 2
4
Freezer Tray Large 242L – Qty 5
4
Freezer Tray Large 312L – Qty 7 Details Range Specific
5
6 7
Compressor housing Laboratory Plus
12
Product Details cont. 5:4 Laboratory Plus Refrigerator/Freezer Combi – FS Details Families 280L
1 2
3
4
9
5
11
6
9
7
8
Compressor housing Laboratory Plus
13
10
1
Bluetooth enabled controller
2
Key lock
3
Movable wire shelves - qty 3
4
Fixed wire shelf - qty 1
5
Wire basket
6
Freezer tray large – qty 2
7
Freezer tray small – qty 2
8
Adjustable feet two at front
9
Antimicrobial handle
10
Door tray shallow – qty 2
11
Door tray deep – qty 1
12
Drip tray
Product Details cont. 5:5 Pharmacy Plus Refrigerators – CT
14
6: Installation Positioning and safely using the Refrigerator WARNING: To reduce the risk of the unit falling over, do not tip beyond 10 degrees •
Make sure the equipment is placed in a dry, wellventilated site, away from heat sources.
•
The equipment must be placed on a level surface. If necessary, adjust the feet on the product so the equipment remains level during operation. See Section 7.
•
The equipment should have enough clearance around it to provide adequate ventilation – 10cm at each side, 6cm at the rear and 2.5cm at the top.
•
Before ANY maintenance activity, pull the plug out of the socket by gripping the plug, DO NOT pull on the plug cord.
•
DO NOT use extension cords.
•
If the main power supply cord is damaged, it should be replaced by a qualified service engineer.
•
DO NOT attempt any repairs to the equipment yourself (apart from those highlighted in the Maintenance and Service Section). Repairs carried out by someone without the relevant training are putting their personal safety at risk and will invalidate your warranty.
•
Do not store explosive substances such as aerosol cans with a flammable propellant in this equipment. WARNING: This equipment is only to be operated by authorized personnel or personnel who have correct knowledge on how the equipment operates.
•
•
15
Use this product only in the way described in the product literature and in this manual. Before using it, verify that this product is suitable for its intended use. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. DO NOT modify system components, especially the controller. Use LEC Medical exact replacement equipment or parts. Before use, confirm that the product has not been altered in anyway
•
Your unit must be properly grounded in conformity with national and local electrical codes. Never connect the unit to overloaded power sources.
•
Disconnect the unit from all power sources before cleaning, troubleshooting, or performing other maintenance on the product or its controls.
Transporting and Moving the Refrigerator The refrigerator must always be moved in the vertical position. The cabinet must not be tilted any more than 40°. If the cabinet is tilted more than 40°, the power supply must not be connected until the equipment has stood upright for at least 24 hours. Necessary equipment to move the product is to be arranged by the user.
Electrical Connection The equipment is intended for connection to alternating current. The connection values for voltage (V) and frequency (Hz) are declared on the name plate in the cabinet. Power must be connected via a wall socket with a switch. It is strongly recommended that the wall socket is easily accessible. All earthing requirements stipulated by the local electricity authority. The cabinet plug and wall socket should give correct earthing. If in doubt, contact your local supplier or an authorized electrician. THIS EQUIPMENT MUST BE EARTHED. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The flexible cord (mains lead) fitted to this equipment has three cores for use with a 3-pin 13-amp plug. If a BS 1363 (13-amp) fused plug is used it should be fitted with a 13-amp fuse. The cores in the mains lead are coloured in accordance with the following code: GREEN AND YELLOW: EARTH BLUE: NEUTRAL BROWN: LIVE These colours might not correspond with the colour markings identifying the terminals in your plug.
Electrical Connections 1: Green Yellow
1
2: Blue
4 3: Brown
2
3
4: 13 Amp Fuse 5: Cord Clamp
5
Note: First Connection to the mains. The equipment provides information about the higher temperature (Hi alarm) till the moment of cooling. The alarm is signalized by a sound signal and “Hi” caption on the display. To mute the alarm touch anywhere on the front surface of the controller. Until the moment of cooling, the alarm is repeated every 10 minutes. Such an operating mode is normal until the required temperature settings are reached.
16
7: Before Switching On Thank you for purchasing this LEC Pharmacy/Laboratory Refrigerator Before you first use this pharmacy refrigerator, please carry out the following actions: •
Check that the refrigerator has not been damaged in any way during transportation.
•
If any damage is found it must be reported to your local dealer immediately.
•
Ensure all packaging has been removed, including cardboard, polystyrene and any tape used to hold shelves in place for transportation.
•
The refrigerator has been cleaned prior to dispatch; however, we advise that it should be cleaned using lukewarm water containing a mild detergent and a soft cloth prior to switching on.
•
This equipment is not intended for use by persons (including children) with reduced physical, sensory, mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the equipment by a person responsible for their safety.
•
Ensure the fridge/freezer is level by adjusting the two feet at the front of the unit. For the larger volume units 310L, 400L, 242L, 312L ensure the third foot is fully up before levelling the unit.
When the unit is level adjust the third foot, so it touches the floor.
17
•
To activate the battery backup, install the fuse as shown here. There are two fuses in the documents bag.
•
We recommend that the refrigerator should be left in an upright position preferably in the place where it will be used for 24 hours prior to switching on for the first time.
8: Operation 8:1 IJ Controller Overview
Air Temp Displayed
Cooling Cycle
Scroll Up Arrow
Display Max Temp
Toggle Air/Load Display
Reset Air & Load Temp
Navi Button (Enter)
Display Min Temp
Unit ON/OFF
Scroll Down Arrow
Evaporator Fan Running
Load Temp Displayed
Controller in alarm Condition
Main Display
Note: Not all the symbols will be displayed together. Symbol
A
L
Description
Function
Air Temperature Displayed
Indicates that the AIR temperature is being displayed as selected by the AIR/LOAD Button.
Scroll Up Arrow
Button to scroll up through menus and values.
Toggle Air/Load Display
Switches between Air and Load temperatures.
Navi Button (Enter)
Used to confirm actions and input values and to unlock the controller by keeping pressed for 3 seconds.
Unit ON/OFF
Press for 3 seconds the unit will swich off. The controller will flash between current selected temperature A or L and “OFF”.
Scroll Down Arrow
Button to scroll down through menus and values.
Load Temperature Displayed
Indicates that the LOAD temperature is being displayed as selected by the AIR/LOAD Button.
Main Display
Temperatures, alarms, menus, parameter values are displayed here.
Controller in Alarm Condition
If this symbol is displayed the controller is in an alarm condition. It will clear when the alarm/fault is cleared.
Evaporator Fan Running
Indicates when the evaporator fan is running under the intelligent fan control system.
Display Minimum Temperature
After unlocking the controller, pressing this button will display the minimum recorded temperature since the last reset.
Reset Air & Load Temperature
Used to access the reset minimum and maximum temperature function. Both Air and Load Temperatures will be reset.
Display Maximum Temperature
After unlocking the controller, pressing this button will display the maximum recorded temperature since the last reset.
Cooling Cycle
Indicates when the appliance is in cooling cycle. Will flash if the controller is waiting to run the cooling cycle. Table** 18
8:2 IJ Controller Default Operating Displays 8:2:1 IJ controller displaying Air Temperature no system faults or alarms.
Press Navigator button once to display compressor and fan status.
8:2:2 IJ controller displaying Load Temperature no system faults or alarms.
Press and hold for 3 seconds to unlock the controller Section 11:1
To switch between Air and Load temperatures see Section 11:2:1
8:2:3 IJ controller displaying Air Temperature no system faults or alarms and displaying compressor and fan status. Cooling Cycle On Fan Running
8:2:4 IJ controller alternating the current Air Temperature and the alarm status HI – High Air Temperature. (HI used only as an example, for a full list of alarms see section 12.
Alarm Status Flashing Note: Temperatures show in all the above displays are for example only. 19