REF 1138 3860+ OPERATION MANUAL MRidium
TM
MRI INFUSION/MONITOR SYSTEM
IRADIMED CORPORATION
MRidiumTM 3860+ MRI Monitor/Infusion System Operation Manual, Part Number 1138 Release 4D, 2017-05 PER ECN 000866
© 2010-2017 IRadimed Corporation IRadimed Corporation 1025 Willa Springs Drive Winter Springs, Florida 32708 U.S.A. Tel 407-677-8022 Fax 407-677-5037 www.iradimed.com
European Authorized Representative Medical Device Consultancy 7 Pinewood Drive Ashley Heath, Market Drayton, Shropshire, UK, TF9 4PA www.medicaldeviceconsultancy.co.uk
CONTENTS
Paragraph Page General Information ... vi Equipment Classification ... vi Intended Uses / About the Pump ... vii Warnings / Precautions...viii User Responsibility ...xiv Definitions...xiv Symbols ... xv 1.0 1.1
1.2 1.3 1.4
1.5 1.6 1.7 1.8 2.0 2.1 2.2 2.3 2.4 2.5
2.6 2.7 2.8 2.9 2.10 2.11
Introduction ... 1-1 Product Description... 1-1 1.1.1 Front of the Pump ... 1-2 1.1.2 Pump Drive Mechanism ... 1-3 1.1.3 Back of the Pump ... 1-4 1.1.4 1120 MRI Power Supply ... 1-5 1.1.5 Front of the Remote Display/Charger ... 1-6 1.1.6 Back of the Remote Display/Charger ... 1-7 Controls ... 1-8 1.2.1 Front Panel Control Keys ... 1-8 Pump Preparation for Use ... 1-10 1.3.1 Administration Sets ... 1-11 1.3.2 Artifacts ... 1-11 Display ... 1-13 1.4.1 Informational Display ... 1-17 1.4.2 User message area ... 1-17 1.4.3 Infusion Parameter Setup Display ... 1-17 1.4.4 Secondary ... 1-18 1.4.5 Bolus ... 1-18 1.4.6 Special Features Setup Menu ... 1-19 User Interface ... 1-19 System Self Test ... 1-19 Maintenance and Operator Verification ... 1-19 Cleaning Instructions ... 1-20 Installation... 2-1 Introduction... 2-1 Unpacking the Pump ... 2-1 Unpacking Remote Display/Charger ... 2-1 Unpacking 3861 Channel B SideCar ... 2-2 Preparing the Pump for Use ... 2-2 2.5.1 Installing Battery... 2-2 2.5.2 Installing Optional Pulse Oximeter Sensor ... 2-2 2.5.3 Removing The Pulse Oximeter Sensor ... 2-2 Mounting on I.V. Pole... 2-2 Operational Checkout of the Pump ... 2-2 2.7.1 Determining the current IV Pump Software revision level:... 2-3 Pump Storage ... 2-3 Remote Display Installation ... 2-3 2.9.1 Charging Battery with the Remote. ... 2-4 Language Options... 2-5 Product Structure ... 2-5
i
3.0 3.1 3.2
3.3
4.0
I.V. Set Preparation for Use ... 3-1 Precautions... 3-1 I.V. Set Priming ... 3-2 3.2.1 I.V. Administration Set 1056 Priming ... 3-2 3.2.2 I.V. ByPass Set 1055 Priming ... 3-2 3.2.3 I.V. Syringe Adapter Set 1057 Priming ... 3-2 3.2.4 I.V. Extension Set 1058 Priming ... 3-3 I.V. Set Insertion and Removal... 3-4 3.3.1 Administration Set Insertion ... 3-4 3.3.2 Administration Set Removal ... 3-4
4.6 4.7
Primary Configuration ... 4-1 4.0.1 Programming a Basic Infusion ... 4-1 4.0.2 Editing the Infusion Program... 4-2 4.0.3 Canceling/Pausing an Infusion... 4-2 4.0.4 KVO (Keep Vein Open) - Infusion Complete... 4-3 4.0.5 Volume Infused ... 4-3 4.0.6 Pump Shut Down... 4-3 4.0.7 Restoring an Infusion following Pump Power Down ... 4-3 Dual Channel Infusion ... 4-4 4.1.1 Dual Channel Infusion Setup ... 4-4 4.1.2 Single Channel/Dual Display Setup ... 4-4 Secondary (“Piggyback”) Infusion Configuration ... 4-5 4.2.1 Priming a Secondary Administration Set ... 4-6 4.2.2 Secondary Infusion Setup ... 4-6 4.2.3 Programming a Secondary Infusion... 4-7 4.2.4 Viewing Primary Settings during a Secondary Infusion... 4-8 4.2.5 Changing Primary Settings during a Secondary Infusion... 4-8 4.2.6 Stopping a Secondary Infusion and Returning to Primary Infusion ... 4-8 4.2.7 Dual Channel Operation... 4-8 Bolus Delivery... 4-9 4.3.1 Bolus Setup and Start ... 4-9 4.3.2 Stopping Bolus Rate Dose... 4-10 4.3.3 Restoring Bolus Dose. ... 4-10 Channel B ... 4-11 4.4.1 Attaching the Channel B SideCar ... 4-11 4.4.2 Detaching the Channel B SideCar... 4-11 Special Features Menu ... 4-12 4.5.1 Dose Rate Calculation ... 4-14 4.5.2 Alarm Volume ... 4-21 4.5.3 KVO Rate ... 4-22 4.5.4 Occlusion Limits ... 4-23 4.5.5 Lock Keys... 4-24 4.5.6 NEXT MENU key ... 4-24 4.5.7 Radio Channel menu ... 4-24 4.5.8 Exiting the Special Features Menu... 4-25 Air Bubble Detection and Reset. ... 4-25 Data Retention... 4-25
5.0 5.1 5.2 5.3 5.4
Alarms... 5-1 Introduction... 5-1 User Messages ... 5-1 Responding to an Alarm ... 5-1 Remote Alarms ... 5-2
4.1 4.2
4.3
4.4 4.5
ii
6.0 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 6.10 6.11 7.0 7.1 7.2 7.3 7.4
7.5 7.6
7.7 7.8 7.9 7.10 7.11 7.12 8.0 8.1 8.2 8.3 8.4 8.5 8.6
Battery Operation ... 6-1 Introduction... 6-1 Inserting the Battery Pack ... 6-1 Charging the Battery Pack ... 6-1 Removing the Battery Pack ... 6-2 Testing the Battery Pack... 6-2 Battery Charge Indicator ... 6-3 Battery Low Indication ... 6-3 Battery Power Gauge ... 6-4 Battery Care and Maintenance: ... 6-4 6.9.1 Introduction... 6-4 6.9.2 1133 Battery Pack Maintenance Checkout Procedure ... 6-4 Battery Pack Replacement ... 6-4 Battery Pack Related Precautions... 6-5 Introduction, Pulse Oximeter, 3860+ ... 7-1 7.0.1 User Warnings and Precautions ... 7-1 Installation ... 7-3 Symbols, Displays, and Controls ... 7-4 7.2.1 SpO2 Symbols ... 7-4 7.2.2 Displays ... 7-5 Operator Verification... 7-7 Operating the 3860+ Pulse Oximeter ... 7-7 7.4.1 Probe Set-up and Use ... 7-8 7.4.2 Applying the Model 1170 Fiberoptic SpO2 Sensor... 7-8 7.4.3 Verifying Operation of the Model 1170 Fiber Optic Sensor ... 7-11 Probe Cleaning ... 7-11 7.5.1 Cleaning the Model 1170 Fiberoptic Sensor and 1171 Sensor Grips 7-11 SpO2 Alarms and Alerts ... 7-11 7.6.1 Patient and Equipment-Related Alarms ... 7-11 7.6.2 Watchdog Alarms ... 7-11 7.6.3 Reviewing, Setting, or Changing Volumes and Alarm Limits ... 7-12 SpO2 Menu Choices ... 7-12 SpO2 Troubleshooting ... 7-13 SpO2 Parts and Accessories ... 7-15 SpO2 Testing Summary... 7-16 Specifications... 7-17 The Masimo Set® Principles of Operation... 7-18 Dose Error Reduction System ... 8-1 Introduction: ... 8-1 DERS Installation ... 8-1 DERS FEATURES AND DEFINITIONS... 8-2 DERS RELATED ALERT AND USER PROMPT MESSAGES ... 8-3 8.4.1 ALERT / PROMPT - MESSAGES, TYPE, CAUSE AND RESOLUTION ... 8-4 DERS Indicators / Status ... 8-6 SETTING UP A DERS PRIMARY INFUSION... 8-7 8.6.1 SETTING UP A DERS PRIMARY INFUSION... 8-7 8.6.2 Adjusting a Dose or the VTBI During an Infusion... 8-14 8.6.3 SETTING UP A DERS BOLUS... 8-15 8.6.4 REPEATING A BOLUS DOSE ... 8-19 8.6.5 Canceling Bolus Delivery ... 8-20 8.6.6 DUAL CHANNEL DERS INFUSION ... 8-21 8.6.7 DUAL CHANNEL BOLUS DELIVERY... 8-23
iii
Appendix A: Specifications ...A-1 Appendix B: Repair ...B-1 Appendix C: Warranty information...C-1 Appendix D: Manufacturers Technical Declaration ... D-1 Appendix E: Accessories ... E-1 Appendix F: Troubleshooting ... F-1 Appendix G: 1119 I.V. Pole Assemblies and Parts Descriptions... G-1 Appendix H: Trumpet and start up curves ... H-1 Appendix I: 1145 Dose Error Reduction System... I-1
iv
FIGURES Figure Page 1-1 Front of Pump ... 1-2 1-2 Pump Drive Door Open... 1-3 1-3 Back of Pump... 1-4 1-4 Model 1120 MRI Power Supply ... 1-5 1-5 Front of 3865 Remote Display/Charger ... 1-6 1-6 Back of 3865 Remote Display/Charger... 1-7 1-7 Front Panel Control Keys ... 1-8 1-8 Setup Display Screens... 1-13 1-9 Running Screens ... 1-15 1-10 Special Features Setup Menu ... 1-18 3-1 Free Flow Preventer ... 3-1 3-2 Roller and Slide Clamps... 3-1 3-3 IV Set Installation ... 3-5 4-1 Primary Pump Setup Screen... 4-1 4-2 Dual Infusion Display ... 4-5 4-3 Secondary Infusion Set-up and Programming Screen ... 4-7 4-4 Bolus Setup Displays... 4-9 4-5 Attaching Channel B “SideCar” ... 4-11 4-6 Special Features Menu ... 4-12 4-7 Dose Rate Calculation Menu ... 4-14 4-8 Primary Screen with Dose Rate Displayed ... 4-17 4-9 Alarm Volume Adjustment Screen... 4-21 4-10 KVO Rate Screen ... 4-23 4-11 Set Comm Channel Displays ... 4-25 5-1 Alarm Display in User Message Area... 5-2 6-1 Battery Installation ... 6-1 6-2 Battery Removal ... 6-2 6-3 Battery Test... 6-3 7-1 3860+ Display w/SpO2 ... 7-4 7-2 Connecting the 1170 Fiberoptic Probe ... 7-9 7-3 Applying the 1170 SpO2 Sensor ... 7-10 7-4 Saturation Charting. ... 7-19
Table Page 5-1 Alarm, Alert and User Prompt Messages ... 5-3 7-1 SpO2 Alarm Limits ... 7-8
v
General Information This document provides the following directions for use: • Single channel pump that provides a full range of features in a compact, easy to use, linear peristaltic pump. • Dual channel pump offers the same features while providing two independent infusion pumps in one instrument. • The Remote Display/Charger Unit allows for remote ability to control the Pump with a total of two channels from outside the MR Scanner. The system is designed for use in the following patient care areas: • MRI (0.2 to 3T systems). • MRI/Recovery. • Pump operable and safe in up to 1 Tesla (10,000 Gauss) magnetic field. EMI Statement: This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to other devices, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Reorient or relocate the receiving device. 2. Increase the separation between the equipment. 3. Connect the equipment into an outlet on a circuit different from that which the other devices(s) are connected. 4. Consult the manufacture or field service technician for help. Mains Disconnection Method: 3860 Pump: Disconnect power cord (1121) from Appliance Inlet on the side of the MRI power supply unit (1120). 3865 Remote/Charger Unit: Disconnect power cord (1128) from Appliance Inlet on the rear of the Unit. Alternate Voltage/Export: For power cord plug types see local country distributor. Unit shipped in USA with US 3 pin power NEMA plug.
3860 EQUIPMENT CLASSIFICATION Classification according to IEC 60601-1 According to the type of protection against electrical shock:
Class I equipment and internally powered
According to the degree of protection against electrical shock:
Type CF (defibrillator-proof) equipment
According to the type of protection against harmful ingress of water:
Ordinary Equipment. Complies with Section 44.4 of the Infusion Pump standard, IEC 60601-2-24.
According to the methods of sterilization or disinfection:
Non-sterilizable. Use of liquid surface disinfects only.
According to the mode of operation
Continuous operation
Equipment not suitable for use in the presence of flammable anesthetic mixture with air or with oxygen or nitrous oxide
vi
About the Pump: Intended Uses Indications for Use: The Iradimed Corporation's MRidium 3860+ MRI Infusion Pump/Monitoring System is intended for general hospital or clinical use by medical professionals whenever it is required to infuse patients with subcutaneous, intra-venous or intra-arterial fluids before, during, or after Magnetic Resonance Imaging (MRI) scans, functioning while either in a stationary or mobile position. The system is useful in the administration of fluids requiring precisely controlled infusion rates. The system can operate in either continuous, intermittent, or bolus delivery mode. The Infusion Pump can be used inside the MRI room mounted outside the 10,000 Gauss line (1 Tesla line), and with shielded magnets of field strength of 3.0 Tesla or less. This device is available for sale only upon the order of a physician or other related licensed medical professional, and not intended for any home use applications. The Pulse Oximeter is used to measure, display, and record functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate of adult, pediatric, and infant patients in an MR environment. Testing of the oximeter was performed in MR conditional environments at 1.5T and 3T. It is indicated for spot checking and/or continuous monitoring of patients who are well or poorly perfused in the MRI. This infusion pump is contraindicated for use on the inlet side of Extra Corporeal Membrane Oxygenation (ECMO) systems where the negative pressure is greater than -100 mmHg as the high negative pressure can result in uncontrolled fluid flow. The MRidiumTM 3860+ Infusion System incorporates a unique ultrasonic motor providing the non-magnetic motor power driving the MRidiumTM 3860+ pumping unit. This allows the MRidiumTM 3860+ to be constructed with minimal magnetic material and safely operable in high magnetic fields. Features include: • Non-magnetic ultrasonic drive motor. • Special aluminum RF noise shielding enclosure. The pump is equipped with a unique battery display that provides the clinician continuous monitoring of battery capacity available. This information is displayed when the instrument is turned on. The Dual Rate Feature allows the pump to administer both primary and secondary solutions at separate flow rates and volumes. Using this feature the clinician can select and start a program for secondary delivery. Upon completion of the secondary dose, the pump can automatically switch over to a primary rate. Both channels of the MRidiumTM 3860+ can be programmed for primary and secondary operation. Optional modes are easily accessed with the press of one key. The Dose Rate Calculator allows the clinician to calculate a dose rate for continuous infusion given concentration and dosage orders. The Bolus Dose feature allows the clinician to set up an initial infusion rate for a specific Bolus volume, automatically followed by a maintenance rate from the same container. A 2.4 GHz wireless link allows communication between the infusion pump and remote display. Qualified service personnel can configure many features of the pump to meet specialized needs. Specific pump menu screens may vary depending on software release being used.
vii
This device is covered under one or more of the following U.S. Patents: 7,267,661 B2, 7,404,809 B2 and International Equivalents 7,553,295, 7,553,882, 8,105,282 B2 and International Equivalents 7,753,882; 8,150,493; 8,690,829; 8,262,642; 8,469,932; 8,105,282; 8,500,694 EP1530440; 1802362; 4597970; 5001845 International Patents Other U.S. and International patents pending. Possession or purchase of this device does not convey any express or implied license to use the device with unauthorized infusion sets, sensors or cables which would, alone, or in combination with this device, fall within the scope of one or more of the patents relating to this device. Masimo®, Masimo SET®, Signal Extraction Technology® and Signal IQTM are trademarks or registered trademarks of Masimo Corporation.
Warnings/Precautions Federal Law in the U.S.A. restricts this device to sale by or on the order of a physician. This device is intended for use by trained medical professionals only. Refer all service to Iradimed Corporation Authorized Service Representatives. The 3860 Pump has been specifically designed for operation inside an MRI Magnet Room, and is designed to operate normally in the presence of most frequently encountered electromagnetic interference in the MRI environment. Under extreme levels of interference, such as in close proximity to an electrosurgical generator, cellular telephone or a 2 way radio normal pump operation may be interrupted. Avoid use of this pump under these conditions. Use only MRI-compatible patient access devices (e.g. needles, luer-ports, etc.) to prevent any possible RF current from reaching the patient's skin. The Remote Display Charger is intended for use in the MRI control room. Do not operate the 3865 Remote Display/Charger inside the MRI Magnet Room. For safe operation, use only Iradimed Corporation recommended MRI-compatible or MRI-safe accessories. The MRI pump must be mounted securely when used in the MRI scan room. Always securely mount the pump using it’s integral pole mount clamp or other mechanical fixing means. Always secure the I.V. Pole wheel locks after positioning within the MRI Magnet Room. Avoid placing the I.V. Set adjacent to any electrical conductor within the MRI bore, which can become heated during MRI scans. The Alarm Sound Volume is adjustable for various clinical environments. Ensure the alarm sound level is appropriate for the use environment in the MRI so that it can be heard above the ambient noise level, especially during scanning. Product damage may occur unless proper care is exercised during unpacking and installation. Do not use the pump if it appears damaged in any way. The battery should be charged before use. Battery may not be fully charged upon receipt. Connect pump to AC power for at least nine (9) hours before placing the pump into use. Always connect the infusion pump power supply or Remote Display/Charger to a properly grounded 3-wire power receptacle. Never use power extension cords. If the quality of the earth grounding is in question, use battery power for the infusion pump. This equipment is not suitable for use in the presence of flammable anesthetic or other gases. Do not use this system in the presences of flammable gases.
viii
Precautions/Continued Arrange tubing, cords and cables to minimize the risk of patient or other equipment entanglement. The pump is not intended for high pressure, high viscosity radiological contrast agents. To avoid patient injury, always respond to Pump or Remote Display/Charger alarms immediately. Never leave the patient with the Pump stopped if the infusion has not been completed. To prevent injury, avoid placement of any NIBP cuff on the limb receiving the I.V. therapy. The Pump contains materials which must be recycled, or disposed of properly. For proper disposal methods, contact your local sales representative or distributor. Hospital personnel must ensure the compatibility of the drugs as well as the performance of each pump as part of the overall infusion. Potential hazards such as drug interactions, inaccurate delivery rates, inaccurate pressure alarms and nuisance alarms may arise from other incompatibilities. MRI pump uses medical grade silicone rubber and PVC tubing. Do not infuse pharmaceuticals or solutions that are incompatible with these materials. Drugs not compatible with silicone rubber or PVC plastics, or drugs not stable under infusion conditions should not be used with this system. Consult the drug labeling to confirm drug compatibility, concentration, delivery rates and volumes are suitable for concurrent delivery, or piggyback delivery (secondary followed automatically by primary). Simultaneously infusing with more than one pump into one patient line may significantly affect the infusion rate of at least one of the pumps. Hyberbaric Chamber Operation: The MRidium system is not certified for use in oxygen enriched environments. It is not intended for use in this environment. Equipment use outside it’s specified environmental conditions can affect infusion accuracy. WARNING: This product may contain a chemical known to the State of California (U.S.A.) to cause cancer, or birth defects or other reproductive harm.
Pump Related Warnings/Precautions This pump is designed to stop fluid flow under alarm conditions. Periodic patient monitoring must be performed to ensure the infusion is proceeding as expected. Immediately respond to a “Close Door” alarm due to imminent lapse in infusion therapy. Immediately respond to the “Check Door” alarm as this indicates possible Free-Flow of IV Fluids. Dropping, or a severe shock to the pump, could result in damage and resultant pump inaccuracy. Refer the pump to qualified service personnel for proper checkout if either of these conditions occur. Do not place the pump into use if it fails any of the Power On Self Tests. Always verify flow rate, VTBI (Volume to be Infused) and/or dose drug entries before starting infusion. When opening the door, always check that the free flow preventer (black slide clamp) is fully pulled outward to the shut off position.
ix
Pump Related Warnings/Precautions (Continued) If questionable Pump operation is observed, or if a System Failure occurs (i.e. an unexplained continuous audible alarm with no displayed values), discontinue use of the Pump and refer it to qualified service personnel. Although unlikely, failure of certain rugged mechanical components, such as the free-flow prevention mechanism could cause fluid delivery limited to the contents of the fluid container. The maximum volume that may be infused under a single fault condition is 0.1 mL. Single fault failure of any electronic or motor control component would result in less than 0.3 mL of unexpected fluid delivery. A small amount of fluid is expelled from the set (less than 0.05 mL) under worse case conditions when the mechanical drive advances to Index each time the pump latch is opened and closed with a set loaded. If potent drugs are being used, take appropriate action to guard against overmedication of the patient. Always set the occlusion pressure alarm limit at the minimum level required for the prescribed fluid therapy. Whenever closing the Pump Door, check to make sure that nothing interferes with the pumping mechanism. During a running infusion, each interruption and re-start of the infusion can add approximately 0.05 mL of delivered fluid to the indicated Volume Infused. There are dangerous voltages present on internal components that may cause severe shock or death upon contact. Never open the pump casing, it’s power supply, or the Remote/Charger when connected to AC Mains power. Disconnect from AC power and remove battery pack prior to servicing or cleaning. Do not operate the pump on patients with the battery removed (pump will stop and not alarm during AC power loss without battery installed). Use of a properly maintained and charged battery will allow proper operation. Do not touch battery connector pins and patient simultaneously. If the Low Battery alarm sounds, connect the pump with its power supply to AC power immediately. Replace blown fuses on the 1120 Pump MRI power supply or Remote Display/ Charger with fuses of the same type and rating only, or a fire hazard could exist. Never use sharp objects (paper clips, needles, etc.) to clean any part of the pump. Keep the pump door latch securely closed when the pump is not in use. This will avoid door latch damage. Do not sterilize the pump or any component by heat, steam, ethylene oxide (ETO), or radiation. The screen displays the VTBI (Volume to be Infused) in whole integers above 99.9. Any fraction of a milliliter delivered is not displayed, but is retained in memory. To avoid damage to the I.V. Pump and Pole, always move the I.V. Pole separately from the patient trolley to prevent accidental entanglement. The pump body is made of aluminum and is non-magnetic. However, when moving the pump within high magnetic fields (>2000 gauss) one might notice Eddy Current effects. These are forces generated in the aluminum which resists motion through the intense magnetic field. Such effects are normal and present no risk of free magnetic movement of the unit. Sensors detect open or poorly shut door clamp and incompletely closed IV Set free flow preventer clamp, generating a “Check Door” alert. Immediate attention should be given to possible free flow.
x
Set Related Warnings/Precautions Always use aseptic techniques. Patient infection could result from mishandled or non-sterile assemblies. Use only Iradimed Corporation MRidiumTM 1000 Series administration sets. The use of other sets will cause improper pump operation resulting in inaccurate fluid delivery. MRidiumTM 1000 Series administration sets are only intended to be used with the MRidiumTM Pump. All infusion administration sets are supplied sterile and are single use only. Do not sterilize or re-use. Patient infection or inaccurate flowrate could result. Prior to use of any Infusion Set, examine the pouch and inspect for damage that could compromise sterility. If the pouch or Set is damaged, discard and use another Set. Administration sets should be changed per the Center for Disease Control (CDC) guidelines or healthcare provider policy. Discard after use. Design use life of I.V. sets is six (6) hours maximum. Disconnect the I.V. line from the patient before starting the priming procedure. Prepare the primary solution container in accordance with the manufacturer’s instructions. The use of positive displacement infusion devices ported together with gravity flow infusion systems into a common I.V. site may impede the flow of the gravity flow system and affect their performance. Hospital personnel must ensure that the performance of the common I.V. site is satisfactory under these conditions. Interconnection with I.V. sets with small inner diameter may affect pump accuracy at high flow rates. Avoid interconnection with small bore diameter I.V. sets (less than 0.050 inch (1.25mm) I.V. tubing) if high flow rates are used. A kinked or occluded I.V. line could cause the pump to operate abnormally and affect the accuracy of the infusion. Before operating this system, verify that the I.V. line is not kinked or occluded. To avoid nuisance alarms, confirm that the fluid source is positioned higher than the pump. Setting the primary rate greater than the secondary rate will result in a more rapid infusion of any residual secondary drug remaining in the line, the administration set, and fluid container. When performing a secondary infusion: • Secondary solution container must be higher than the primary solution container. • The Secondary VTBI (Volume to be Infused) setting must be equal to the volume in the secondary container. This requires consideration of such variables as factory overfill, medication additions, etc. Underestimating the volume will cause the remaining secondary solution to be infused at the primary rate; overestimating will result in the primary solution being infused at the secondary rate. Multiple doses from a single container are not possible. Air bubbles may form distal to the pump as a result of normal out-gassing of dissolved air in the fluid. This may occur if a chilled solution is being used, if the pump is mounted significantly above the patient, or with certain fluids known to routinely outgas. In these cases, an air eliminating filter may be required. During a prolonged infusion, routinely inspect I.V. Set, access device and patient line assemblies for proper attachment and orientation.
xi
Set Related Warnings/Precautions (Continued) Variations of head height, back pressure, selected catheter type, or any combination of these may affect rate accuracy. Factors that can influence back pressure are: I.V. set configuration, I.V. solution viscosity and I.V. solution temperature. Back pressure may also be affected by catheter type. The use of pumping infusion devices ported together with gravity flow infusion systems into a common IV site (primary IV set with secondary IV lines) can affect the accuracy of the gravity flow systems, and result in unintended flow rates from these gravity systems. Always ensure the common IV site is acceptable for use under these conditions. Reference to specific drugs and default parameters are provided for the user’s convenience. Always refer to the specific drug product labeling for information concerning appropriate administration techniques and dosages.
Battery Pack Related Warnings/Precautions The 1133 Battery Pack contains several lithium-polymer cells and an integral safety circuit. As these cells age, they can expand due to internal gas release, which is anticipated for this type of cell. However, if excessive expansion occurs, this can result in the battery case expanding (swelling), and possibly cause failure of the battery case, cells, or safety circuit. If this is observed, remove the Battery Pack from use and replace it as soon as possible. The 1133 Battery Pack contains protective circuitry to prevent catastrophic battery failure. If the Battery pack is damaged, this protective circuitry may not prevent battery failure. Remove the Battery Pack from use if the Pack becomes damaged, or the potential for Battery Pack damage is suspected. Do not use a damaged or swollen 1133 Battery Pack. Avoid damage to the 1133 Battery Pack by impact, dropping, overheating, or mechanical abuse. Never compress, drop, shock, or strike the 1133 Battery Pack. Never use objects that could puncture the internal battery cells. Any of these actions can cause the battery cells to heat, smoke, or cause catastrophic battery failure, which could result in fire. Do not attempt to disassemble the 1133 Battery Pack. Damage caused by disassembly or tool use can result in catastrophic battery failure, which could result in fire. If the 1133 Battery Pack case begins to expand and/or swell, discontinue battery charging and use immediately, and replace the Battery Pack. Continued charging will cause further Battery Pack case expansion, with possible battery case fracture, and potential electrolyte leakage. If the 1133 Battery Pack becomes damaged, avoid contact with the battery cell electrolyte. If the electrolyte contacts the skin or eyes, seek medical attention immediately. If the 1133 Battery Pack shows sign of the battery case expanding (swelling), remove the Battery Pack from use and replace it as soon as possible. In extreme conditions, this swelling can cause the 1133 Battery Pack to become jammed or stuck within the 3860 Pump or 3865 Remote Display, and/or cause the Battery Pack plastic case to burst open. If this occurs, do not use tools that could cause damage to the internal battery cells. Refer to the 1125 Service Manual for removal under these conditions. Under no circumstances should Battery Packs or the internal cells be incinerated as this can cause an explosion.
xii
Pulse Oximeter Related Warnings/Precautions USE ONLY Recommended SpO2 Fiberoptic Sensors (Sensors containing electrical conductors will cause patient burns). Do not use cables or sensors that contain conductive wires. This device is intended only as an adjunct device in patient assessment. It must be used in conjunction with other methods of assessing clinical signs and symptoms. Iradimed SpO2 sensors are reverse gender connectors (female connector on sensor cable / male connector on pump) than that found with other non-MRI pulse oximeters. This is done to help prevent improper sensor connection to the pump. Use only recommended pulse oximeter sensors. These sensors are manufactured to meet the accuracy specifications for Iradimed Corporation’s pulse oximeters. Using other manufacturers’ sensors can result in improper pulse oximeter performance. The fiberoptic cable for this device is extremely sensitive and must be handled with caution at all times. DO NOT use a damaged sensor. Refer to the User Warnings and Precautions area in Section 7 (Pulse Oximeter) for additional Pulse Oximeter related warnings and precautions.
xiii
User Responsibility This product will perform in conformity with the description contained in this users manual and accompanying labels, inserts, etc., when assembled, operated, maintained and repaired in accordance with the instructions provided. This product must be checked and calibrated periodically. A malfunctioning product should not be used. Parts that are broken, missing, plainly worn, distorted or contaminated should be replaced immediately. Should such repair or replacement become necessary, refer unit to Iradimed Corporation qualified service personnel. This product or any of its parts should not be repaired other than in accordance with written instructions provided by the manufacturer, or altered without written approval of Iradimed Corporation. The user of the product has the sole responsibility for any malfunction which results from improper use, faulty maintenance, improper repair, damage or alteration by anyone other than Iradimed Corporation or Iradimed Corporation authorized service personnel.
Using This Manual Read this manual completely before attempting to use the pump. Warning, Cautions and Notes. This manual contains three levels of precautionary information. • A Warning alerts the user that there is a possibility of injury or death to a human being. • A Caution alerts the user that there is a possibility of damage to equipment. • A Note contains essential information deemed especially important by Iradimed Corporation.
Definitions Channel A Channel B hr KVO mL Primary Rate Secondary VI VTBI %SpO2
The designation for the first infusion channel. All pumps contain at least one linear peristaltic pump head for one infusion line. The designation for the second infusion channel. The second infusion pump module is optional and some pumps may not contain it. hour. Keep-Vein-Open. milliliter. Main Infusant for the prescribed I.V. therapy. The infusion settings that are implemented after any secondary infusion sequence is complete. Infusion rate in mL / hr. The first infusion settings to be implemented in an infusion sequence when more than one infusion is delivered with the same pump channel, sometimes referred to as “piggyback.” Volume Infused in mL. Volume To Be Infused in mL. Percent of Oxygen (pulse) Saturation.
xiv
Symbols Attention: Consult Accompanying Documents, or alternately, Caution
Appropriate for use in MR environment
Defibrillator proof Type CF Applied Part
MR Conditional. Only appropriate for use in MR environment with manufacturer’s defined restrictions.
Date of Manufacture
MR Unsafe. Not appropriate for use in MR environment (i.e. inside the MR magnet room)
Indicates that the device conforms to the Medical Device Directive
Single Use Only
Direct Current
Product Serial Number
Indicates Infusion Sets comply with requirements specified in ISO 8536ISO 8536-8-IS-P 8 (Infusion Equipment with pressure infusion apparatus up to a maximum of 200 kPa).
Alternating Current
Drops per milliliter specification for I.V. Set is identified on Drop Symbol
Do not Resterilize
Lot or batch code for I.V. Set will be identified near Lot Symbol
Product Part Number
Approximate Set priming volume
Expiration date for I.V set will be identified near hour glass symbol
Main Battery Capacity. (X inside Icon denotes no battery installed.)
Denotes I.V. Set was sterilized with Irradiation
AC Power is connected to 100-240 VAC
Contains Lithium. Requires proper disposal/recycling of this material.
Secondary Infusion Mode
Power On, or On
Volume to be Infused
Power Off, or Off
Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician
Volume Infused
Maximum rated load is 20 Kg.
Both Input/output connection. Allows data communication.
xv
Do not discard. Contact recycler for proper disposal
Input Connection Only
EC Authorized Representative
2.4 GHz Radio is communicating.
Percent of Oxygen (pulse) Saturation
Output Connection Only
BPM
Pulse Rate in Beats/Minute
Radio-Frequency transmission source
Pulse Detected
Storage Temperature Range
Telecommunications Alert Symbol - Class 2 (European Union Countries Only)
This product has been certified to UL60601-1 and applicable Particular Standard IEC 60601-2-24, for which the product has been found to comply by Intertek.
Spare Battery Capacity. (X inside Icon denotes no battery installed.)
2.4 GHz Radio Antenna
Refer to operating instructions for important safety information.
xvi
STBY
Infusion has been paused. Press start to resume infusion
>>>
Alternating symbols indicate Channel A is infusing
<<<
Alternating symbols indicate Channel B is infusing
Sterile Fluid Path
Do not use if package is damaged
Keep equipment below this line on the 1119 IV Pole.
Replace fuse with 1 Amp, 3AG, 250V time delay (Slow Blow) fuse.
All Iradimed products conform to European Union Directives 2011/ 65/EU for RoHS Compliance.
Unique Device Identification (UDI).
xvii
SECTION 1 INTRODUCTION 1.0 Introduction. The MRidiumTM 3860/3860+ MRI Infusion/Monitor System is intended for patients that require medications and/or fluids during an MRI scan. This pump is designed to provide infusion therapy at all stages of the MRI procedure. This system is for use by trained medical personnel only and is not intended for long term patient care outside of an MRI environment. This system provides the following features: • Continuous Infusion, Dose Rate Calculation Program and Automatic Bolus. • Automatic free-flow protection for the I.V. line. • Up to two channel fluid delivery, each with separate primary/secondary programmable rate and VTBI, into single or separate IV lines. • Rechargeable long life battery. Lasts up to 12 hours at 125 mL/hr. • Status indicator light above door (Red for Alarm, Green for Infusing). • Soft keys to program various functions. • Large LCD display screen. • Up and Down arrow control keys and 10 Key numeric Keypad to change numeric values quickly and easily. • Handle for easy portability, weighs less than 11.5 pounds. • I/O port for Service related functions. • Optional second channel with the addition of the 3861 SideCarTM. • Optional remote control with the additional 3865 Remote Display/Charger. • Optional Dose Error Reduction System with dedicated drug library card. • Memory card slot for easy upgrades. • On-Board Masimo SpO2 Monitor (3860+ only). • Expanded Infusion Rate Range from 0.1 to 1400 ML/Hr.
CAUTION: Handle the MRidiumTM 3860/3860+ MRI Infusion/Monitor Pump and
additional accessories with care. If it should be dropped or severely jarred, it should be immediately taken out of service and inspected by a qualified biomedical technician. 1.1 Product Description. The MRidiumTM 3860 MRI Infusion/Monitor System is designed for operation in the MRI environment and may be used on the patient near the MRI magnet (up to the 1.0 Tesla or 10,000 Gauss Line). Operating on battery power, when fully charged this system will provide up to 12 hours of operation at an infusion rate of up to 125 mL/hr and at least four (4) hours at rates up to 999 mL/hr. The MRidium Wireless Remote Display allows for remote ability to control the Model 3860 MRidium MRI Infusion/Monitor Pump with a total of two channels from outside the MR Scanner. It utilizes the same user interface as the 3860 infusion pump and will allow adjustment of all pump parameters, rates, titration, volume to be infused, starts, stops, and resetting alarms. The large clear display shows all pump information at your desk top from the control room. The Wireless remote also acts as a charger for a backup or spare battery pack for the 3860 MRidium MRI Infusion/ Monitor Pump. It utilizes a wireless link at 2.4 GHz for easy installation with no image artifacts. NOTE: The 3860/3860+ pumps will only communicate with 3865 wireless Remote/Display units. NOTE: The Remote Display/Charger only operates on AC Mains Power. This unit does not operate on battery power. This unit does not sound a Low Battery alarm for the Spare Battery being charged.
1-1