NKV-550 Series Recruitment Maneuver Tip Sheet Rev B

Tip Sheet

1 Page

Tip Sheet  NKV-550 Ventilator  Recruitment Maneuver  NKUniversity.org  Starting a Recruitment Maneuver (RM) 1.  Click the RM app icon and set the Control settings for the RM (see table).  Setting Default  Setting Range  Δ PC: 15 cmH2O  10 to 20 cmH2O  2.  The graph will show the preview of the procedure based on the Control settings.  I:E ratio: 1:1  4:1 to 1:299  RR: 20 bpm  10 - 25 bpm  3.  Press the “Start” button. During the procedure, the 		 FiO2: 21 to 100% ventilator will ventilate the patient using the identified 		 Max. pressure allowed: 30 cmH2O Control settings (in table), temporarily overriding the 		 PEEP increment each PEEP step: 5 cmH2O currently set ventilation settings. - If patient effort is detected, a “Patient Effort Detected” alarm message will be displayed.  21 to 100% 30 - 55 cmH2O 2 - 5 cmH2O  Duration for each PEEP step: 20 sec  20 to 180 sec  PEEP after end of procedure: 25 cmH2O  0 - 30 cmH2O  - A “Hold Step” button allows the clinician to extend the time for the current PEEP Step. Pressing “Resume Step” will continue the procedure. - If the procedure needs to be stopped prior to being completed, press the “End” button. - Follow the warnings and precautions in the device operator manual to ensure the safety of the procedure operation.  Conclusion of Recruitment Maneuver 1.  When completed, the ventilator will continue to use the 		 RM Control settings to ventilate the patient, except for the PEEP setting set at the start of the procedure. - The PEEP setting will remain at the level where the procedure concluded.  2.  In order not to revert to the original ventilation settings, 		 within 5 minutes, the clinician must either:  a) 		  Press the “End” button to cancel this PEEP and 		 resume normal ventilation.  b) 		  Press the “Go to PEEP titration” button to perform 		 PEEP titration.  3.  The clinician can study the relationship between PEEP and various other parameters (e.g., compliance, SpO2, EtCO2.)  NOTE:  Do not perform a Recruitment Maneuver if:  		 - Patient is alert and not sedated		 		  - Patient is not on invasive ventilation  		  - Patient’s hemodynamic or respiratory conditions are unstable or become unstable  us.nihonkohden.com  Nihon Kohden University is a registered trademark of Nihon Kohden. Exceptional Solutions, Simply Delivered is a trademark of Nihon Kohden. VTSI 003 [B] - CO-2456  For 24/7 ventilator support, please call 1-855-550-VENT or email ventilator@nihonkohden.com
File Type: PDF
File Size: 134 KB
File Name: NKV-550 Series Recruitment Maneuver Tip Sheet Rev B.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions