NSK NAKANISHI

High Speed Drill System

Surgic XT Plus Operation Manual

Operation Manual

11 Pages

SURGERY SYSTEM  OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference... OM-E0454E 003 ’11...  S   Classification of equipment • Type of protection against electric shock : – Class l equipment • Degree of protection against electric shock : – Type BF applied part • Method of sterilization or disinfection recommended by the manufacture : – See 8... terilization • Degree of protection against ingress of water as detailed in the current edition of IEC 60529 : – Foot Control: IPX8 (Protected against the effects of continuous immersion in water) • Degree of safety of application in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide : – Motor, Foot Control: Category AP Equipment •Mode of operation : – Intermittent operation  Cautions for handling and operation Read these safety cautions thoroughly before use and operate the product properly... hese indicators are to allow you to use the product safely, prevent danger and harm to you and others... hese are classified by degree of danger, damage and seriousness... ll indicators concern safety, be sure to follow them... lassification WA R N I N G  Degree of Danger or Damage and Seriousness Explains an instruction where personal injury or physical damage may occur... CAUTION  Explains an instruction where minor to medium injury or physical damage may occur... NOTICE  Explains an instruction that should be observed for safety reasons... • Surgic XT Plus should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, the Control Unit should be observed to verify normal operation in the configuration in which it will be used...  When operating this system always consider the safety of the patient...  Read this Operation Manual before use, and fully understand the functions of each part for operation key...  Do not attempt to disassemble the Control Unit /Foot Control / Micromotor nor temper with the mechanism...  Check for vibration, noise and overheating before use and if any abnormalities are found in use, stop using immediately and contact your dealer...  Use an electrical outlet that is grounded...  Do not drop, hit, or subject to excessive shock...  Do not bend the Irrigation Tube while the water pomp is operating... t could cause tube breakage...  Do not use bent, damaged or sub-standard burs... he Shank could bend or brake...  Do not exceed the recommended speed...  After each Operation, be sure to lubricate and sterilize the handpiece as soon as it’s cleaned... lood coagulation can cause corrosion and rusting... owever, do not lubricate the Micromotor... il could generate excessive heat and cause damage...  The Control Unit can be cleaned with a moist cloth... isconnect the power supply before cleaning... he Control Unit and the Foot Control cannot be sterilized by any method...  When the product is very frequently used, consider the maintenance of a small stock of replaceable parts...  Do not disconnect the Motor Cord from the motor...  Do not wipe with or, clean or immerse in, high acid water or sterilizing solutions...  Follow the table below for the motion time of motor and handpiece... ontinuous Continuous time use over a long time may cause the overheating of the handpiece, which in turn ON OFF may result in an accident...  min... 0 min...  Applied parts for patient and/or operator is Handpiece... NOTICE • Turn off the Main Power Switch after each use...  For service requirements and spare parts contact your dealer...  The use of NSK genuine pre-sterilized, disposable Irrigation tube Kit is recommended... Temperature  Humidity  Atmospheric pressure  Use  Between 0-40˚C (32-104˚F)  Between10-85% RH  Between 700- 1060hPa  Store Transportation  Between -10-60˚C (14-140˚F)  Between 10-85%RH  Between 500-1060 hPa  1... afety precautions prior to use Read Handpiece’s Operation manual carefully before use... Intended to Use Surgic XT Plus is intended for use in dental oral surgery and surgical procedures by qualified personnel... WARNING  ** No moisture condensation in the Control Unit... * Use at outside of these limits may cause malfunction... The system may present a possibility of malfunction when used in the presence of an electromagnetic interference wave... o not install the system in the vicinity of the device which emits magnetic waves... urn off the power switch of the Control Unit of this system when an ultrasonic oscillation device or an electrode knife is located in the vicinity is used... CAUTION • Surgic XT Plus needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information...  Portable and mobile RF communications equipment can affect Surgic XT Plus... o not use RF equipment outskirts for the product...  The use of accessories, Motors and cables other than those specified, with the exception of Motors and cables sold by the manufacturer of Surgic XT Plus as replacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of the Control Unit...   2  English  Thank you for purchasing the NSK Surgic XT Plus surgical unit... e recommend that prior to use, you carefully read this document regarding instructions for use, handling method, or maintenance check so that you can carry on using the unit in the future... n addition, keep this operation manual in a place where a user can refer to it at any given time...
File Type: PDF
File Size: 661 KB
File Name: surgic_xt_plus_operation_manual.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions