OLYMPUS

EVIS EUS ULTRSOUND BRONCHOFIBERVIDEOSCOPE

EVIS EUS ULTRASOUND BRONCHOFIBERVIDEOSCOPE Cleaning Guide

1 Page

ENDOSCOPE CLEANING GUIDE  All steps of manual cleaning for endoscope are done in detergent solution or water completely, except for flushing with air and drying the external surfaces at the end of cleaning.  EVIS EUS ULTRASOUND BRONCHOFIBERVIDEOSCOPE OLYMPUS BF-UC190F/290F WARNING WARNING This workflow is a summary of the cleaning steps necessary to properly reprocess your BF-UC190F/290F and does not include disinfecting/sterilizing steps. Follow the detailed steps instructed in the latest ENDOSCOPE REPROCESSING MANUAL for BF-UC190F/290F.  Precleaning at Bedside  1  Leakage Testing  2  Remove the balloon, and wipe the insertion section  Aspirate water and air through the instrument/suction channel  Flush water and air through the balloon channel  Suction valve  3 Detach the suction and biopsy valve, and attach the US connector cap (MAJ-2295)  4  Confirm that air bubbles do not emerge from endoscope 30 sec  water : 30 ml ×3 air : 30 ml ×3  water : 10 sec air : 10 sec  Syringe Irrigation port  Manual Cleaning  5  Prepare the following brushes Cleaning brush  Thoroughly wipe all external surfaces in the detergent solution  6  Brush from the suction cylinder to the distal end  or BW-411B  7  Brush from the instrument channel port to the distal end  Brush the suction cylinder  BW-411B or BW-15B  BW-411B or BW-15B  BW-15B  8  BW-411B or MH-507  or BW-7B  BW-400B  Channel opening cleaning brush or BW-411B  MH-507  Manual Cleaning  9 Brush the instrument  10 Brush from the irrigation port  channel port  11 Brush the irrigation port (balloon channel)  (balloon channel) to the distal end  BW-411B or MH-507  BW-400B or BW-7B  BW-411B or MH-507  12 Brush the balloon grooves  BW-411B or BW-15B  BW-411B or MH-507  Manual Cleaning  13 Aspirate the detergent solution (with attaching MAJ-222)  14 Completely immerse the endoscope and the suction cleaning adapter (MAJ-222) in the detergent solution  MAJ-222  15 Aspirate the detergent solution  16 Flush the detergent solution (through the balloon channel)  30 ml ×1  30 ml ×1  Suction pump  30 sec Detergent solution  Manual Cleaning  Rinsing  17 Wipe all external surfaces and  18 Completely immerse and gently  leave in the detergent solution  rinse the endoscope and MAJ-222 in the water  19 Aspirate water, air  water : 30 sec air : 20 sec  20 Dry the external surfaces by wiping with clean cloths  Suction pump  Flush water, air water : 30 ml ×5 air : 30 ml ×5  N8601427-032019
File Type: PDF
File Size: 1.53 MB
File Name: OLYMPUS - N8601427-032019 - EVIS EUS ULTRASOUND BRONCHOFIBERVIDEOSCOPE Cleaning Guide - 2019-03.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions