OLYMPUS

OLYMPUS EndoCapsule System

ENDOCAPSULE 10 SYSTEM Preparation and settings for capsule endoscopy Quick Reference Guide Feb 2014

Quick Reference Guide

2 Pages

ENDOCAPSULE 10 SYSTEM Preparation and settings for capsule endoscopy This quick reference guide is only a summary of the ENDOCAPSULE instructions for use. For detailed operating instructions, be sure to follow the ENDOCAPSULE instruction manual that was included with your device when purchased. Before the examination  1   . Log in to workstation. Register 2 patient information and initialize recorder.  2   Refer to the back page Note: Check that the battery is fully charged (green light is lit).  1. Place recorder in the cradle.  4 3  3  3. Insert antenna sheet into the cover. Orange colored lines printed on the surface should face front. The cable always stays on the patient’s left side.  5  4. Fasten the antenna belt around the patient’s body. The alignment hole should fit the umbilical area.  8 3  7  7. Insert the capsule activator into the capsule container. The LED should start blinking.  6  5. Attach the recorder holder on the left side of the patient’s body. Connect the recorder and the antenna unit. Slide the connection part until it clicks.  6. Press “POWER” for at least 1 sec. Patient ID and name are displayed on the upper left screen.  IMPORTANT NOTICE TO PATIENTS  8. Press “MENU” and select “Real Time View”. Confirm that images are received properly.  When removing the capsule from the container, be careful NOT to touch the top cover of the capsule. Otherwise, clear images may not be captured.  After the capsule ingestion 9. Press “MENU” and select “Real Time View”. Confirm that images from the body are being received properly. If necessary, images can be played back or captured.  9  10  10. Lock the button operation. Go to “Patient Message” and press “MENU” for at least 2 sec. When patient guidance is activated, the patient does not necessarily need to touch the recorder. Beep or vibration will stop after 30 sec.  After the examination 11  12  13  11. Unlock the recorder. Press “MENU” for more than 2 sec. Open “Real Time View” to confirm that the examination is complete. 12. Place recorder in the cradle. 13. A message will be displayed on the screen. Click “OK” to start downloading image data. When completed, a check mark will be displayed on the main screen.
File Type: PDF
File Size: 634 KB
File Name: ENDOCAPSULE 10 SYSTEM Preparation and settings for capsule endoscopy Quick Reference Guide Feb 2014.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions