OLYMPUS

OLYMPUS Scopes Colono and Sigmodo System

CF and PCF-H190xx Series EVIS EXERA III COLONVIDEOSCOPE Caution Instructions Sept 2021

Caution Instructions

2 Pages

INSTRUCTIONS CAUTION FOR FLEXIBILITY ADJUSTMENT CONTROL OPERATION EVIS EXERA III COLONOVIDEOSCOPE  OLYMPUS CF-H190L/I, OLYMPUS CF-HQ190L/I, OLYMPUS PCF-H190L/I, OLYMPUS PCF-H190DL/I, OLYMPUS PCF-HQ190L/I, OLYMPUS PCF-H190TL/I  WARNING • Never perform flexibility adjustment without viewing the endoscopic image or while the endoscopic image is frozen. Patient injury, bleeding, and/or perforation can result. • Do not use the endoscope if the index markings (“”, “1”, “2”, “3”) on the flexibility adjustment ring and the “ ” mark at the bottom of the grip section are not clearly visible. If the operator is uncertain of the flexibility of the insertion tube, insertion and manipulation of the endoscope may cause patient pain, injury, bleeding, and/or perforation. • If the flexibility adjustment ring becomes jammed during an examination, immediately stop the examination and withdraw the endoscope from the patient. Continued use of the endoscope under this condition could result in patient injury, bleeding, and/or perforation. • Never perform flexibility adjustment while the EndoTherapy accessory extends from the distal end of the endoscope. Patient injury, bleeding, and/or perforation can result. • Regardless of the flexibility of the endoscope’s insertion tube, it can cause patient injury, bleeding, and/or perforation if it is forcibly inserted, withdrawn, and/or twisted with excessive force. • The flexibility of the insertion tube of the CF-H190L/I and CF-HQ190L/I can be adjusted to less than, equal to, or more than that of the CF-Q160L/I. The ranges of the flexibility adjustment of the CF-H190L/I and CF-HQ190L/I are equal to that of the CF-H180AL/I. The flexibility of the insertion tube of the PCF-H190L/I, PCF-H190DL/I, PCF-HQ190L/I, and PCF-H190TL/I can be adjusted to less than, equal to, or more than that of the PCF-140L/I. The ranges of the flexibility adjustment of the PCF-H190L/I, PCF-H190DL/I, PCF-HQ190L/I, and PCF-H190TL/I are equal to that of the PCF-H180AL/I. The insertion tube of the endoscope should be adjusted to the appropriate flexibility for each case. Always confirm the flexibility of the insertion tube by holding the insertion tube with two hands before inserting it into the patient, and adjust the flexibility as necessary according to the case, region, and patient’s condition during an examination. If you are unsure of the appropriate flexibility of the insertion tube, set it to the most flexible condition. Continuing the examination while the insertion tube is set to an inappropriate degree of flexibility may cause patient pain, injury, bleeding, and/or perforation. • Do not change the insertion tube’s flexibility abruptly. Patient pain, injury, bleeding, and/or perforation can result. • If the endoscopic image moves suddenly or is lost while you are changing the insertion tube’s flexibility, stop changing the flexibility and restore the optimal field of view. Moving the flexibility adjustment ring without a clear endoscopic image may cause patient pain, injury, bleeding, and/or perforation. • If the patient complains of pain while you are changing the insertion tube’s flexibility, stop changing the flexibility and ensure the safety of the patient. • If the rigidity of the insertion tube has to be increased during an examination, confirm that there are no loops or excessive bends in the insertion tube (if necessary, use fluoroscopy or, for CF-HQ190L/I, PCF-H190DL/I, and PCF-HQ190L/I, use an endoscope position detecting unit) before increasing its rigidity. If the force required to turn the flexibility adjustment ring is greater during the procedure than it was when inspecting the endoscope, it may mean that the insertion tube is excessively bent inside the patient. In this case, straighten the insertion tube as much as possible before attempting to increase the rigidity. Failure to do so may cause patient pain, injury, bleeding, and/or perforation.
File Type: PDF
File Size: 142 KB
File Name: CF and PCF-H190xx Series EVIS EXERA III COLONVIDEOSCOPE Caution Instructions Sept 2021.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions