PillCam

pH Monitoring Systems

Bravo Quick Reference Guide Rev 02 Feb 2019

Quick Reference Guide

2 Pages

BRAVO™ CALIBRATION-FREE REFLUX TESTING SYSTEM Quick reference guide  Step 1: Prepare the capsule delivery device  Figure 1  Open the plastic cover  1) Check the expiration date on the capsule. 2)	Without bending or kinking the delivery device, carefully remove it from the external shipping box, and then from the inner pouch (Fig. 1). 3)	Remove the capsule’s plastic cover, and magnetic clip. The capsule will automatically turn on when the magnetic clip is removed. 4) Set the magnetic clip aside (Fig. 2). 5)	After opening the capsule package, make sure the capsule trocar needle is not advanced (Fig.3).  Remove magnetic clip  Figure 2  Step 2: Prepare the vacuum pump 1) 2) 3) 4)  Make sure the vacuum flow knob is turned to maximum. With your gloved finger covering the suction chamber, verify that the vacuum gauge reading is at least 550 mmHg. Make a note of the gauge reading (Fig. 4). Remove your finger from the suction chamber. Verify that the vacuum gauge reading drops by at least 50 mmHg to 500 mmHg or lower. Turn off the vacuum and detach the tubing from the delivery device.  Correct  Incorrect  Trocar needle Suction chamber  Step 3: Start the recording 1) If the recorder is turned off or in sleep mode, turn it on. Make sure it is fully charged. 2) From the main menu, select Start Study and press Enter. 3)	If you see a “Last study not uploaded!” message, it means the recorder has detected existing data from a previous study that has not been uploaded. 4)	To stop and upload the existing data, press Cancel and connect to the PC. Follow the instructions on the recorder. When the data is uploaded, start the new study again by selecting Start Study from the main menu. 5)	To continue (overwrite the existing data without uploading it), press Next and then Yes to confirm. 6)	The recorder will start searching for the capsule's signal, and the “Clearing data...” message will appear, followed by “Waiting for pH capsule 1.” 7)	When you see the message,” Does this pH capsule ID number match the delivery device number?” Press Yes or No. You’ll find the capsule ID on the package label. Bravo™ calibration- free reflux capsules have a 5-digit ID; Bravo™ reflux capsules have a 4-digit ID. If the ID doesn’t match, the search will begin again. 8)	If the recorder still does not recognize the capsule or displays a capsule mismatch error, repeat the procedure. 9) If this is a two-capsule study, repeat the process. 10)	When capsule recorder pairing is complete, the recorder will automatically start recording and the screen will display the symptom buttons. 11) Verify that the recorder is displaying pH values and that the capsule status LED on the recorder is blinking blue.  Figure 3  A. Connect vacuum hose B. Place finger over suction chamber C. Remove finger  Figure 4  vacuum port  500 600 700  400  300 200 100 0  mmHg  500 600 700  400  300 200 100 0  mmHg  vacuum hose
File Type: PDF
File Size: 833 KB
File Name: CA-ET-0080-E-BravoCalibrationFreeSystem-QuickReferenceGuide.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions