V500 Service Card IPM-L Rev 21.0

Service Card

4 Pages

Result Sheet Test instructions / Service Card IPM-L Workstation Critical Care Part number: Location:  Serial number:  Department:  Cust. invent. no.:  Maintenance interval:  Other / Delivery date: Key  Applies to Test instructions / Service Card IPM-L Revision 21.0  Test  = OK = Spare part used  !  = Error / Report  /  = Accessory not available  -  = Not applicable  Test  Result  Result  1 Device configuration  3.1.5  1.1    3.1.5.1  Reference value    3.1.5.2  Recurrent test    3.1.6  Device configuration  1.1.1   / OK +  Serial numbers (if not otherwise recorded)  Device leakage current  Application components for measurement of leakage current from application component  µA µA OK    1.1.1.1  C500    1.1.1.2  V-unit  txt    1.1.1.3  Inspiratory safety valve (inspiration unit)  txt    1.1.1.4  Disposable expiratory valve (YES/NO)  txt    3.1.7.1  Reference value  µA    1.1.1.5  Adult expiratory valve (reusable)  txt    3.1.7.2  Recurrent test  µA    1.1.1.6  Additional reusable adult expiratory valve  txt  3.2  Electrical safety according to IEC 60601-1  txt  3.1.7  Applied part leakage current, mains on applied part, type BF    1.1.1.7  MCable-Mainstream CO2 (CO2 sensor) option  txt    3.2.1  Visual inspection  OK    1.1.1.8  Neonatal expiratory valve option  txt    3.2.2  Protective earth resistance  Ω    1.1.1.9  Additional neonatal expiratory valve option  txt  3.2.3    1.1.1.10  GS500 option  txt    3.2.3.1  Normal condition (N.C.) IEC 60-601-1  µA    1.1.1.11  PS500 option  txt    3.2.3.2  Single fault condition (S.F.C.) IEC 60-601-1  µA    1.1.1.12  Trolley option  txt    3.2.3.3  Normal condition (N.C.) UL 60-601-1  µA    1.1.1.13  Nebulizer ejector additional hardware option (without serial number) (Yes or No)  txt    3.2.3.4  Single fault condition (S.F.C.) UL 60-601-1  µA    1.1.1.14  Neonatal flowmeter additional hardware option (without serial number) (Yes or No)  txt  3.2.4  Earth leakage current medical device  Patient leakage current    3.2.4.1  Normal condition (N.C.) DC IEC 60-601-1  µA    3.2.4.2  Normal condition (N.C.) AC IEC 60601-1  µA  2 Maintenance parts    3.2.4.3  Single fault condition (S.F.C.) DC IEC 60601-1  µA  2.1    3.2.4.4  Single fault condition (S.F.C.) AC IEC 60601-1  µA    3.2.4.5  Normal condition (N.C.) DC UL 60-601-1  µA    3.2.4.6  Normal condition (N.C.) AC UL 60-601-1  µA  1.1.2  Software versions Maintenance intervals, overview  2.1.1  Maintenance intervals and required sets and parts  2.2  Maintenance parts by specified interval    2.2.1  V-unit, battery M7 NM2,5  dat  4 Function and condition test    2.2.2  V-unit, particle filter (O2 filter)  dat  4.1  General condition check 4.1.1    2.2.3  V-unit, air filter  dat    Medical device  OK    2.2.4  V-unit, Spirolog sensor cable harness  dat    4.1.2  Accompanying documents  OK    2.2.5  (Option) GS500, room air filter (filter mat)  dat    4.1.3  OK    2.2.6  (Option) GS500, air filter blower unit (microfilter)  dat  Rating plates, labels and notices on the medical device    2.2.7  (Option) PS500, battery set PS500 (Service) 15Ah  dat    4.1.4  Rating plates, labels and notices on the installed options  OK    2.2.8  (Option) PS500, battery set PS500 (Service) 24Ah  dat    2.2.9  (Option) Medication nebulizer, pressure regulator (O2-side)  dat  2.3  Maintenance parts as required  4.2  C500 and V-unit condition test    4.2.1  C500  OK    4.2.2  V-unit  OK  4.3  Condition test, options    4.3.1  (Option) MCable Mainstream CO2 module M11.1 (CO2 sensor)  OK    4.3.2  (Option) Neonatal flow measurement  OK    4.3.3  (Option) Drug nebulizer  OK    4.3.4  (Option) Trolley  OK    4.3.5  (Option) Gas cylinder holder  OK  3 Electrical safety 3.1   Electrical safety of V-unit or ME system according to DIN EN 62353 (IEC 62353) 3.1.1  3.1.2  Visual inspection  OK  Protective earth resistance    3.1.2.1  Maximum measured value.  Ω    4.3.6  (Option) Hose holder  OK    3.1.2.2  Maximum measured value of ME system.  Ω    4.3.7  (Option) GS500  OK    3.1.3  Protective earth resistance measuring points  OK    4.3.8  (Option) PS500  OK    3.1.4  Applied parts for device leakage current  OK    4.3.9  (Option) Cable duct  OK  Revision 21.0  Workstation Critical Care  1/4
File Type: PDF
File Size: 76 KB
File Name: V500 Service Card IPM-L Rev 21.0.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions