SATELEC ACTEON

Universal Wrench

SATELEC Wrenches Manual Pre-Disinfection, Cleaning and Sterilization Instructions

6 Pages

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches Caution Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine content. The pH of detergents/disinfectants must be between 7 and 11. The cleaning method for wrenches recommended by Satelec is manual or automated. All devices must be carefully cleaned and must be sterilized after cleaning prior to use. The sterilization parameters are only valid for correctly cleaned devices. Wrenches must be cleaned with extreme care. It is the responsibility of the end user to ensure that all equipment used to treat Satelec devices is properly installed, validated, maintained and calibrated. Whenever possible, a washer/disinfector should be used for wrenches. Prevent the overloading of wash baskets for ultrasonic cleaning or cleaning in a washer/disinfector.  Cleaning/sterilization cycle limits  Repeated treatment cycles that include ultrasonic cleaning, manual washing and sterilization have minimal effects on wrenches. End of service life is normally determined by wear and damage due to use.  Important − Soiled devices should be separated from non-contaminated devices to avoid contamination of personnel or surroundings. − Wipe blood and/or debris from the wrenches to prevent it from drying onto the surfaces. − Cover the wrench with a soft lint-free cloth dampened with purified water to prevent blood and/or debris from drying.  Containment and transportation Soiled devices must be transported separately from non-contaminated devices to avoid contamination.  Preparation for pre-disinfection/cleaning It is advisable to treat devices immediately or as soon as possible after use. Satelec devices must be treated within two hours of use.  Pre-disinfection/Cleaning – Manual method  Equipment: soft-bristled brush, soft lint-free swab, lint-free cloth, enzymatic or alkaline cleaner, ultrasonic cleaner.  Cleaning instructions of SATELEC wrenches ● J81009 ● V1 ● (13) ● 11/2013 ● RA14US010A SATELEC • A company of ACTEON Group 17 av. Gustave Eiffel • BP 30216 • 33708 MERIGNAC cedex • FRANCE Tel + 33 (0) 556 34 06 07 • Fax + 33 (0) 556 34 92 92 E-mail: satelec@acteongroup.com • www.acteongroup.com
File Type: PDF
File Size: 133 KB
File Name: SATELEC ACTEON - J81009 - SATELEC Wrenches Manual Pre-Disinfection, Cleaning and Sterilization Instructions - 2013-11 - V 1.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions