Solar

CASE Exercise Testing System

CASE 8000 PM Inspection Report Template June 1999

Template

4 Pages

CASE 8000  DPMFRM-022 30 Jun 1999  Preventive Maintenance Inspection Report  Page 1 of 4 Customer______________________________ Customer Number______________________ Date___________ FE ___________________________________ FE ID________ Call Number______________________________ Equipment Serial Number ________________ Software Revision _________  Configuration (ä) ___ 12SL ___ Data Storage on File Server  ___ Remote Viewing  ___ Full Disclosure  Tools 1. Leakage tester 2. Standard hand tools  3. Multimeter 4. Service Manual (p/n 415047-001)  5. ESD Mat and Wrist Strap  Visual Inspection (ä) Inspect the following for excess wear and/or any visual signs of damage. 1. __Coiled patient cable 3.____AC power cord 2. __Patient leadwires 4.____Chassis hardware  Cleaning (ä) 1. ___ Clean all internals of dust  2. ___ Clean external surfaces  Calibration (ä) 1. ___ Writer Tests  2. ___ Key Pad Test  Electrical Safety Checks (ä) Refer to PM Application Form DPMAPP-001-4 class __ for leakage standards for specific voltages. 1. ___ Wall Receptacle Test 2. ___ Ground Continuity (Impedence of protected connection) Test(≤ .1Ω or ≤.2Ω w/power cord) 3. Leakage Ground(Earth) wire leakage to ground test Chassis(Enclosure) leakage to ground test Source Risk(Patient cable leakage to ground) Leakage Sink Risk(Patient cable leakage into patient leads) Leakage  Normal ___ ___ ___ NA  Open Reversed ___ ___ ___ NA  Closed Normal Reversed NA NA ___ ___ ___ ___  ___ ___  Checkout Procedure (ä) A.___ Attach ECG simulator, press the RHYTHM key and check the report for proper data, paper tracking and clarity. B.___ Select a protocol and start treadmill(or ergometer) to verify speed and grade( or workload for ergometers) are operating properly. C.___ Depress the Emergency stop button(if installed) while the treadmill(if installed) is running at 3 m.p.h. to verify the treadmill stops correctly. D.___ Depress the Treadmill Stop button on the CASE 8000 stress keyboard while the treadmill(if installed) is running at 3 m.p.h. and verify the treadmill stops correctly. E.___ Perform the Keyboard Test using the Service Screen. F.___ Perform Writer Diagnostics from the Service Screen.  Template Revision D
File Type: PDF
File Size: 12.5 KB
File Name: CASE 8000 EXER TESTING SYSTEM SERVICE MANUAL_SM_2000656-009_C.PDF

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions