Valleylab

Medtronic Electrosurgical Generators

TrueClear System Quick Start Guide March 2021

Quick Start Guide

1 Page

TruClear SYSTEM QUICK START GUIDE ™  1. SET UP CANISTERS ■ Insert specimen trap  2. ACTIVATE HYSTEROLUX™ FLUID MANAGEMENT SYSTEM Suction Lever to 45 degrees  ■ Connect bottom port to vacuum source  Vacuum Source (suction source)  ■ Set side suction lever to 45 degrees  Suction Regulator (set to 150–300 mm Hg)  ■ Connect jumper tubes ■ Connect color-coded tubing to corresponding canister (blue, white)  Turn machine on. Tissue Trap  Patient Drape (blue)  Plug in cartridge and wait for “Tubeset Accepted” on screen.  Spike fluid bag. Open clamps.  Turn on suction and press start to initiate instrument recognition. Wait until complete. Close inflow.  Reset deficit.  Line up inner black line with outer black line on device.  Turn suction lever to on position.  Place cutting window against pathology. Depress footswitch to begin resection.  Handpiece Outflow (white)  3. CHOOSE BLADE Soft tissue devices Oscillate mode: ON Default speed: <800> Optimal speed: <1500> Dense tissue devices Oscillate mode: OFF Default speed: 1100 Optimal speed: 2500  Switching modes:  4. WINDOW LOCK†  72202536 – TruClear™ Soft Tissue Shaver Mini 72204064 – TruClear™ Dense Tissue Shaver Mini 7209509 – TruClear™ Soft Tissue Shaver Plus  Turn suction lever to off position. Attach device to handpiece. Insert into scope. Position so cutting window is visible.  72203012 – TruClear Dense Tissue Shaver Plus  1. Tap oscillate button. 2. Depress footswitch.  Change 1. Push up/down button speed: 		 on system. 2. Depress footswitch.  ™  Tap  1.  © 2021 Medtronic. All rights reserved. Medtronic, Medtronic logo and Further, Together are trademarks of Medtronic. ™* Third party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company. 03/2021 - US-UW-2100014 - [WF#1528323]  Depress and hold window lock button on footswitch.  Depress  2. The TruClear™ dense tissue shaver mini is shipped with the window lock preset  †  To review the information needed to understand the use of these products, including indications for use, contraindications, effects, precautions and warnings, please consult the product’s Instructions for Use prior to use.
File Type: PDF
File Size: 842 KB
File Name: TrueClear System Quick Start Guide March 2021.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions