Advanced Service Training Guide
41 Pages
Preview
Page 1
ELI 280 ADVANCED SERVICE TRAINING
®
Welch Allyn ELI 280 Advanced Service training
1 xxxxxx rev rev 1 1 DD-MMM-YYYY DD-MMM-YYYY © © 20XX 20XX Hill-Rom Hill-Rom Services, Services, Inc. Inc. ALL ALL RIGHTS RIGHTS RESERVED. RESERVED. xxxxxx
ELI 280 ADVANCED SERVICE TRAINING
ELI 280 Unique Features • Bright 10.1” Color LCD with antismudge resistive touchscreen display • 5 minute Full disclosure buffer (used for Best 10)
• Veritas Automatic Interpretation • Easy upgrade capability via .sno file: Interpretation, Communication options, DICOM, and Storage.
2 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
Resistive Touch Screen Display Resistive Touch Screen This is not an I-Phone or an I-Pad! No Multi Touch When touched, the flex layer moves past the spacer layer and contacts stable layer Point of contact creates a voltage divider in the X and Y directions The Stable Layer is a Glass layer
3 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
ELI 280 Power up: • When on battery: • Briefly press the on/off button • When on AC: briefly press the on/off button or touch the screen (cold start: 3 sec, hot start: 0 seconds) • When in standby: • Briefly press the on/off button Power down: • On Battery: press <gears> and <Off> • On AC: Press on/off button until it does not lit anymore
4 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
ELI 280, navigation Use icons on touchscreen Press if icons are not visible
Enter patient data Record resting ECG (double press for stat ECG) Record rhythm ECG (ELI will print until manual stop) Synchronise with ELI-link to store data, send to EMR, retrieve worklist...
Configuration menu
5 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
Settings: Display Control Simplicity Menu settings for real time display or during ECG review ▪ Touch screen display provides a quick navigation for the selecting: ▪Display Format (Default: 12x1) ▪Display Speed (Default: 25 mm/s) ▪Display Gain (Default: 10mm/mV) ▪Display Filter (Default: 300Hz)
6 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
Demographics ID formats for selection are: ▪ Short ▪ Long ▪ Custom ID –Can be created through any of our partners, or ELI Link
Short
Customizable mandatory fields for transmitting that are yellow turn to orange once the field is entered.
Long
The unit will not transmit records unless the mandatory fields are populated
7 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
ELI 280 - ECG Input WAM - Wireless Acquisition Module • For superior versatility and ease of use, a digital front end that guarantees less noise and data quality • 40 KHz sampling/sec/channel • Remote control keys for easy and fast ECG acquisition or Rhythm printout. • LED indication • No color: Off state • No color, beeping: WAM not paired • Yellow: Lead fail • Green: Power w/all leads connected
8 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
ECG Input ECG port for AM12 is shared with an internal USB port that holds the UTK (WAM transceiver) A setting in the software defines if the UTK or AM12 port is active (never both at the same time)
9 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
Patient directory Search by name, or ID ▪ Type in one or two letters OR numbers and the directory moves to the closest proximity of the requested patient record
10 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
Configuration Screen To access the Configuration screen, start at the Home screen and press GEARS. Press ADVANCED, then enter admin password To access the Service screen, press SERVICE.
11 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
Configuration menu Caution: Before making any changes, press <Print> to print the complete configuration! ECG - Default settings for ECG-related parameters ▪ Filter, Interp on/off, Reasons, Delete Rule, QTcB/QTcF, Best 10/Last10, Pacer channel, Display and Print speed, Rhythm settings System ▪ Volume, ID Format, Height/Weight, Sync Mode, Cart number, Caps lock, Site number, Site Name, Mandatory Fields, Delete Timeout, Encryption Key LAN and WLAN ▪ Network settings including Sync IP and Port number Password ▪ Change Technician and Administrator passwords
12 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
Service Menu Calibrate Cue ▪ Open paper door, pull ½ sheet paper out, close door, press button Auto Test ▪ Tests the flash memory Firmware / Config Files / Options File ▪ Used for upgrades Dump Logs ▪ Transmission and battery logs Dump Records ▪ Copies all records to a USB flash drive Writer Test ▪ Tests the printer
13 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
Service Menu Caution: These functions can affect the ability to use the device
Erase Records ▪ Permanently erases all records. There is a yes/no prompt Test Configuration ▪ This will reset the unit to factory default settings. No prompts Clear Flags ▪ Removes the transmitted, printed and marked as deleted flags, this means that a new sync action will transmit all records again! Fill Directory ▪ Used for testing, this will fill the memory with records that are not marked as deleted and will cause the unit to not be able to save additional ECGs. First Time Boot ▪ Used for initial factory programming. This will reset the unit to factory defaults.
14 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
User Interface Features Patient storage options to suit storage need ▪ 40 patient storage (standard) ▪ 200 patient storage (optional – qualifies as an upgrade) BEST 10 – Unique, Time Saving, Quality ECG ▪ Automatic selection of the BEST 10 seconds of noise free ECG (5 minutes buffer) ▪ The device needs at least 27 seconds of good data before an ECG can be taken Erase Records ▪ Ability to delete (erase) individual/single ECG records from the directory of the unit ▪ Option in the Service Menu: Ability to Delete all records easily
15 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
Backpanel 2 USB ports for ECG input: ▪ External for AM12 ▪ Internal for UTK when WAM is used Select active port in settings The other USB ports on the back cannot be used for ECG input.
USB Host (AM12) USB Device
USB Host
RJ45
RJ11
Antenna
AC Inlet
16 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
Communications Options LAN ▪ Faster and more reliable integrated chipset ▪ If wireless is enabled, LAN will also be enabled WLAN ▪ Support for the most common encryption standards (WEP, WPA, WAP2, LEAP/PEAP, WPA2-EAP-TLS) ▪ Operates in A/B/G/N band – both 2.4ghz & 5ghz
17 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
Communications Options USB direct connect (USB B port) ▪ When connected, the ELI 280 will be recognized by Windows as an external drive ▪ Simply connect the ELI 280 to a PC and drag and drop records into ELI LINK Transmission to USB Memory stick (USB Host) ▪ Dump Records option in the Service Menu ▪ Plug a memory stick in the Host USB port and SYNC the unit: records will be “transmitted” to the memory stick.
PDF generated via ELI LINK 3.10 or later ▪ The USB transmission or file transfer can be perfectly integrated with ELI LINK. ▪ With ELI LINK and its import folder, the user can generate PDF files (and other formats) automatically 18 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
ELI 280 Service 2 boards: ▪ Touchscreen controller ▪ Main PCBA (3 versions: no comms / WLAN / Modem) ▪ Main PCB includes power section ▪ Main PCB holds programmable items: SN & options ▪ SN programming after replacing main PCBA, only allowed once (PROM functionality) – Distributors and customers can contact technical support to request a preprogrammed mainboard, old mainboard must be returned. – Required info: Device SN and LAN MAC Address ▪ Display / touchscreen is integrated in top housing, cannot be replaced separately ▪ Printer can be replaced as a whole or each part individually – Printer requires calibration of Q-sensor (= part of conformance testing) 19 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ELI 280 ADVANCED SERVICE TRAINING
ELI 280 service issues Display problems ▪ Try Hard reset: press –hold power button, wait for 3 times off-on and then a few more seconds, after reboot, device should come up with screen calibration procedure ▪ Open unit and verify connections to screen ▪ Replace top housing (incl. screen) Cue sensor calibration: • pull out paper so that Cue sensor ‘sees’ white and select Cue sensor calibration in service menu
20 xxxxxx rev 1 DD-MMM-YYYY © 20XX Hill-Rom Services, Inc. ALL RIGHTS RESERVED.