ZIMMER

ROSA System

ROSA 3D Exams Acquisition Protocol

Acquisition Protocol

3 Pages

ROSA® Acquisition Protocol If you have any questions, please contact Medtech Customer Service. This acquisition protocol (MRI, CT scan, DTI, PET scan, X-Ray images) has to be followed for image acquisition of a patient undergoing a surgery assisted with the ROSA device.  3D Exams Imaging system  Recommended settings     Modality : CT, MR, PT (mandatory) When using PET-CT exams for planning, first load the CT exam then load the PET exam. Both exams shall have been acquired within the same reference. MRI acquisition 3T and 7T can only be used for exam fusions. Avoid using it as reference exam for laser registration due to image distortion.      Patient orientation : Prone or supine position Contrast agents authorized Table height must remain constant during acquisition     For registration with fiducial markers, include all skin or bone fiducials. For surface matching registration, do not cover the nose and the forehead. External elements (eg. noise and light isolation, strap, etc.) shall not cover the nose and the forehead area, to avoid any skin deformation or imaging degradation. For registration with stereotactic frame, include frame fiducials Do not include table, head clamp or external device in the field. Define the Field of View (FOV) in the Region Of Interest (ROI) to improve the spatial resolution.  Acquisition field         Do not use special characters in patient name Format supported (mandatory): o DICOM 3.0, DICOMDIR o Implicit VR Endian, Explicit VR Little Endian, Explicit VR Big Endian o JPEG Baseline, JPEG Lossless, JPEG-LS-Lossless, JPEG-LS-Lossy Avoid Lossy compressed format, which may impact image quality. Acquisition orientation: o non-tilted, non curved, slices parallel to each other (mandatory) o axial acquisition for registration with stereotactic frame, preferably axial or coronal acquisition for other registration methods. Pixel size, image size, acquisition orientation and table height must remain constant during acquisition Number of slices must be ranging between 40 and 512 o If number of slices inferior to 40, it may impact efficiency of automatic fusion o If number of slices superior to 512, it may impact device latency Slice thickness preferably constant and recommended between 0.6 and 0.8mm. When superior to 1.25mm, the device accuracy is not guaranteed. Contiguous slices : avoid gap and overlap between slices o In case of gap in the acquisition, the software will perform an interpolation which may impact device accuracy. o In case of overlap, the system will ignore the overlapping data which may impact device accuracy. Grayscale pixel data : Monochrome2 (mandatory) Image bit depth: signed and unsigned 8 bits, 16 bits. o In case of bit depth on 32bits, the software will truncate the data bit depth from 32 to 16 bits. Do not import derived series.    Maximum image resolution of 512x512 pixels. Images with higher resolution will be downscaled at import. All slices with same resolution (mandatory)      Acquisition properties     Resolution  ROSA-167H-EN ROSA® Acquisition Protocol  1/3
File Type: PDF
File Size: 639 KB
File Name: ROSA-167H-EN Acquisition protocol (English).pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions