ZONARE
z.one Service Manual Release 4.X Rev D July 2011
Service Manual
304 Pages
Preview
Page 1
REVISION HISTORY REV
DESCRIPTION
DATE
A B
Initial Release to support Version 4.0 Software/Hardware Updated software release and Scan Module support
1/09 4/09
C
Updated to 4.1/4.2 software releases
9/09
D
Updated Release to Support 4.7 SW & Product Changes
7/11
Q00169 Rev D
Page 2 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
TABLE OF CONTENTS 1
2
3
4
INTRODUCTION... 10 1.1
Purpose ... 11
1.2
Product Overview ... 11
1.3
Product Features ... 12
1.4
Definitions/Acronyms ... 13
1.5
Documentation Conventions... 15
SAFETY ... 17 2.1
CAUTIONs and WARNINGs During Service/Operation ... 17
2.2
Battery WARNINGs ... 18
2.3
CAUTIONs During Service... 18
2.4
Battery CAUTIONs ... 19
2.5
USB Memory Stick CAUTIONs ... 19
2.6
Networking CAUTION ... 19
SYSTEM SPECIFICATIONS ... 20 3.1
System Dimensions ... 20
3.2
Displays... 21
3.3
Image Archive or Export Storage ... 22
3.4
Transducers... 22
3.5
Accessories/Options ... 26
3.6
Peripherals... 26
3.7
Site Requirements ... 26
3.8
System Power ... 27
3.9
System Power Protection ... 27
3.10
Electrical Specifications ... 27
3.11
Temperature, Humidity, Pressure Limits ... 29
3.12
Device Classification ... 30
3.13
Safety Standards... 30
3.14
DICOM Standard... 30
3.15
Product Labeling ... 30
TOP-LEVEL PRODUCT OVERVIEW... 35 4.1
Major Assembly Identification ... 35
4.2
Transducers... 35
Q00169 Rev D
Page 3 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
5
6
4.3
Accessory Components... 36
4.4
SmartCart Major Assemblies (shown with MTP Multi- probe Option) ... 37
4.5
miniCart Major Assemblies ... 38
4.6
SmartCart User Interface Controls (Overview) ... 39
4.7
Scan Engine User Interface Controls (Overview)... 41
4.8
SmartCart User Interface Controls (Detailed) – Version 1 ... 42
4.9
SmartCart User Interface Controls (Detailed) – “Enhanced” Version (2)... 47
4.10
SmartCart & miniCart Keyboard Controls (Detailed) ... 52
4.11
Scan Engine User Interface Controls (Detailed) ... 55
4.12
SmartCart Rear I/O Panel: Layout & Functional Definitions ... 58
4.13
miniCart I/O Connections: Layout & Functional Definitions ... 58
4.14
Scan Engine/Scan Module Rear I/O Ports: Layout & Functional Definitions ... 59
4.15
AVED: Audio-Video Extension Device - I/O Panel: (Option)... 59
SYSTEM UNCRATING & INSTALLATION PROCEDURES ... 61 5.1
Product Shipment ... 61
5.2
Electrical Requirements... 61
5.3
Environmental and Space Requirements ... 61
5.4
Uncrating... 61
5.5
Mechanical Verification... 65
5.6
System Installation: ... 65
5.7
Transporting - Shipping the Scan Engine/Scan Module... 74
BASIC SYSTEM CONFIGURATION... 75 6.1
7
8
Basic System Configuration Procedures ... 75
ARCHIVE MENU FUNCTIONS ... 83 7.1
“Media” & “Store/Print” Button Configuration... 83
7.2
“Exam Export” Menu ... 86
7.3
“Exam Management” Menu... 87
7.4
Archive “Export” – OPTION menu... 93
7.5
“Serial Port” Setup - (Export Calc Report Data)... 95
DICOM CONFIGURATION ... 98 8.1
“DICOM” Configuration Overview ... 98
8.2
“DICOM” Configuration Parameter Definitions:... 99
8.3
Z.ONEUltra Pre-Install Survey Form (Sample Only) ... 102
Q00169 Rev D
Page 4 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
8.4
“DICOM” Configuration Procedure - Menus ... 106
8.5
“Network” Setup ... 114
8.6
“FTP” Setup ... 116
9
ADVANCED SYSTEM SETUP CONFIGURATION ... 118 9.1
“Security” Setup Menus ... 118
9.2
“Power Save” Setup Menu ... 120
10
GENERAL PROCEDURES... 122
10.1 11
Installing USB Memory Stick, into the Scan Engine/Scan Module... 122
FUNCTIONAL DESCRIPTIONS... 123
11.1
Overall System ... 123
11.2
SmartCart ... 125
12
POWER & SIGNAL DISTRIBUTION DIAGRAMS ... 129
12.1
SmartCart Power Module Block Diagram (Basic) ... 130
12.2
SmartCart Power Module Block Diagram (Detailed) ... 131
12.3
SmartCart Main Board Cable Connect Diagram (Original DVD Config) ... 132
12.4
SmartCart Main Board Cable Connect Diagram (IDE/SATA Adapter DVD Config) ... 133
12.5
SmartCart Main Board Cable Connection Diagram (USB Style DVD Configuration) ... 134
12.6
miniCart AC/DC Power Distribution Diagram ... 135
13
FUNCTIONAL BLOCK DIAGRAMS... 136
13.1
Z.ONEUltra Overall System Block Diagram (SmartCart w/Cardiac-Option Configuration) 137
13.2
miniCart Configuration: Overall System Block Diagram... 138
13.3
Z.ONEUltra SmartCart - Cardiac Module (CW/ECG) Option - Block Diagram... 139
14
ASSEMBLY DIAGRAMS... 140
14.1 15
SmartCart: Power Module Functional Identification ... 140
PERIPHERALS & ACCESSORIES ... 141
15.1
DVD/CD Burner - (Internal)" ... 141
15.2
AVED – Audio Video Extension Device Box - (Option)" ... 142
15.3
SONY UP-D897 USB Digital Printer ... 148
15.4
SONY UP-D25MD Color Printer ... 154
15.5
HP LaserJet Network (REPORT) Printer ... 156
15.6
2- Pedal Footswitch ... 160
16
SOFTWARE PROCEDURES... 161
Q00169 Rev D
Page 5 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
16.1
SCAN ENGINE: Standard Software Installation/Upgrade Procedure... 161
16.2
SCAN ENGINE (Only) “Advanced” Software Installation Procedure ... 163
16.3
SCAN MODULE: Standard Software Installation/Upgrade Procedure... 167
16.4
SCAN MODULE: “Clean” Software Install Procedure (“SERVICE” key)... 169
16.5
SCAN MODULE: “Clean” Software Install Procedure (Undocked or Auto-Load) ... 170
16.6
FTP Site Access: Software/File Downloads from Zonare ... 172
16.7
“DIAGNOSTIC” Panel Operations ... 172
17
CLEANING AND DISINFECTING PROCEDURES... 183
17.1
SmartCart ... 183
17.2
Scan Engine... 184
17.3
Transducers ... 185
18
MAINTENANCE – CALIBRATION PROCEDURES ... 189
18.1
Foreword ... 189
18.2
List: Maintenance Procedures... 189
18.3
List: Calibration Procedures ... 189
18.4
PIC Reset (Power Supply) Procedure ... 190
18.5
Z-PAK “RECONDITION” Procedure - (SmartCart) ... 190
18.6
UI Lift (Gas spring) Release Cable Adjustment - (SmartCart) ... 192
18.7
Touchscreen Calibration - (Scan Engine) ... 193
18.8
Display Monitor Adjustment – User Settings ... 195
19
SYSTEM TROUBLESHOOTING... 197
19.1
Foreword ... 197
19.2
Technical Support Contact Information ... 197
19.3
Troubleshooting... 199
19.4
System Status LED & Error Code Definitions... 206
19.5
Scan Engine Fan Operation ... 214
19.6
SmartCart LCD Display Troubleshooting ... 214
19.7
Battery Performance – Charge Times - Reconditioning ... 215
20
REPAIR PROCEDURES ... 217
20.1
Foreword ... 217
20.2
Recommended Tools ... 217
20.3
Hardware Service/Replacement Procedures (SmartCart)... 217
20.4
Hardware Service/Replacement Procedures (miniCart) ... 277
Q00169 Rev D
Page 6 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
20.5
Hardware Service/Replacement Procedures (Scan Engine) ... 287
20.6
Hardware Service/Replacement Procedures (Transducers)... 288
20.7
Service Software Procedures... 291
21
PART NUMBER INFORMATION ... 293
21.1
SmartCart ... 293
21.2
miniCart ... 296
21.3
Scan Engine... 298
21.4
Scan Module ... 299
21.5
Transducers ... 300
21.6
Peripherals ... 302
22
INDEX ... 303
Q00169 Rev D
Page 7 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
TABLE OF FIGURES FIGURE 1: LABEL, SCAN ENGINE – SERIAL/PART NO... 31 FIGURE 2: LABEL, SCAN MODULE – SERIAL/PART NO. ... 31 FIGURE 3: LABEL, SCAN ENGINE BATTERY (VERSION 1) - SERIAL/PART NO. ... 31 FIGURE 4: LABEL, SCAN ENGINE BATTERY (VERSION 2) - SERIAL/PART NO. ... 31 FIGURE 5: LABEL, 100V-240V SMARTCART REAR PANEL - SERIAL/PART NO... 32 FIGURE 6: LABEL, SMARTCART Z-PAK BATTERY ... 32 FIGURE 7: LABEL, MINICART REAR PANEL - SERIAL/PART NO... 32 FIGURE 8: LABEL, LINEAR ARRAY TRANSDUCERS - SERIAL/PART NO... 33 FIGURE 9: LABEL, CURVED ARRAY TRANSDUCERS - SERIAL/PART NO... 33 FIGURE 10: LABEL, ENDO CAVITY TRANSDUCER - SERIAL/PART NO. ... 33 FIGURE 11: LABEL, PHASED TRANSDUCERS - SERIAL/PART NO. ... 33 FIGURE 12: LABEL, SPECIALTY TRANSDUCERS - SERIAL/PART NO... 33 FIGURE 13: LABEL, AC POWER BATTERY ADAPTER ... 34 FIGURE 14: LABEL, AC POWER ADAPTER POWER SUPPLY ... 34 FIGURE 15: Z.ONEULTRA MAJOR ASSEMBLY ILLUSTRATIONS ... 35 FIGURE 16: TRANSDUCER ILLUSTRATIONS ... 35 FIGURE 17: ACCESSORIES ... 36 FIGURE 18: SMARTCART KEYBOARD CONTROLS (OVERVIEW)... 39 FIGURE 19: SMARTCART USER INTERFACE (VERSION 1) CONTROLS (OVERVIEW)... 39 FIGURE 20: SMARTCART USER INTERFACE (“ENHANCED” VERSION) CONTROLS (OVERVIEW)... 40 FIGURE 21: SCAN ENGINE USER INTERFACE CONTROLS (OVERVIEW) ... 41 FIGURE 22: SMARTCART USER INTERFACE LAYOUT – VERSION 1... 42 FIGURE 23: SMARTCART USER INTERFACE LAYOUT – “ENHANCED” VERSION (2) ... 47 FIGURE 24: SMARTCART KEYBOARD LAYOUT ... 52 FIGURE 25: MINICART KEYBOARD LAYOUT ... 52 FIGURE 26: SCAN ENGINE USER INTERFACE LAYOUT (DETAILED) ... 55 FIGURE 27: SMARTCART REAR I/O PANEL ... 58 FIGURE 28: MINICART USB HUB CONNECTIONS ... 58 FIGURE 29: SCAN ENGINE/SCAN MODULE REAR I/O CONNECTIONS ... 59 FIGURE 30: AVED OPTION - I/O PANEL (SMARTCART)... 59 FIGURE 31: MAIN SHIPPING CONTAINER REMOVAL ... 62 FIGURE 32: LOADING RAMP LOWERING ... 62 FIGURE 33: REMOVABLE SECTION OF SHIPPING BASE ... 62 FIGURE 34: REMOVING PROTECTIVE STORAGE BAG ... 63 FIGURE 35: BRAKE RELEASE OF WHEELS... 63 FIGURE 36: BATTERY PACK INSTALLATION ... 66 FIGURE 37: SCANNER DOCKING IN SMARTCART ... 66 FIGURE 38: SCAN ENGINE TO MINICART DOCKING... 67 FIGURE 39: AC POWER ADAPTER ... 70 FIGURE 40: 2-BAY BATTERY CHARGER ... 72 FIGURE 41: INSTALLING USB MEMORY STICK... 122 FIGURE 42: SMARTCART: BRAKE MECHANISM ... 127 FIGURE 43: SMARTCART: HEIGHT ADJUSTMENT MECHANISM ... 128 FIGURE 44: SMARTCART: POWER MODULE BLOCK DIAGRAM (BASIC) ... 130 FIGURE 45: SMARTCART: POWER MODULE BLOCK DIAGRAM (DETAILED) ... 131 FIGURE 46: SMARTCART: MAIN BOARD CABLE CONNECTION DIAGRAMS (ORIGINAL DVD) ... 132 FIGURE 47: SMARTCART: MAIN BOARD CABLE CONNECTION DIAGRAMS (IDE/USB ADAPTER STYLE DVD) ... 133 FIGURE 48: SMARTCART: MAIN BOARD CABLE CONNECTION DIAGRAMS (USB STYLE DVD DRIVE) ... 134 FIGURE 49: MINICART: AC/DC POWER DISTRIBUTION DIAGRAM ... 135 FIGURE 50: OVERALL SYSTEM BLOCK DIAGRAM (ADVHDWE SCAN ENGINE & SMARTCART W/CARDIAC OPTION) ... 137 FIGURE 51: OVERALL SYSTEM BLOCK DIAGRAM (ADVHDWE SCAN ENGINE & MINICART)... 138 FIGURE 52: SMARTCART: CARDIAC OPTION (CW/ECG) MODULE BLOCK DIAGRAM ... 139
Q00169 Rev D
Page 8 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
FIGURE 53: SMARTCART: POWER MODULE FUNCTIONS DIAGRAM ... 140 FIGURE 54: AVED: AUDIO VIDEO EXTENSION DEVICE I/O PANEL DIAGRAM ... 144 FIGURE 55: MENU SETTINGS (UP-D897)... 150 FIGURE 56: OPERATOR CONTROLS (UP-D897) ... 152 FIGURE 57: APPROVED DISINFECTANTS TABLE (IMMERSION-METHOD)... 185 FIGURE 58: APPROVED DISINFECTANTS TABLE (WIPE-METHOD) ... 186 FIGURE 59: TRANSDUCER IMMERSION LIMITS ... 187 FIGURE 60: MINICART 13” DISPLAY: RECOMMENDED SETTINGS -... 195 FIGURE 61: SMARTCART 19” DISPLAY: RECOMMENDED SETTINGS ... 195 FIGURE 62: TRANSDUCER CONNECTOR PIN DAMAGE – (EXAMPLE) ... 199
Q00169 Rev D
Page 9 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
1
INTRODUCTION
USA, Canada, Asia
ZONARE Medical Systems, Inc. 420 N. Bernardo Mountain View, CA 94043 Toll-free line (in USA only) live-voice support: ... 1-877-913-9663 Standard line (USA & International) live-voice support: ... 1-650-316-3199 Tech Support fax line ... 1-650-230-2817 Customer Support E-Mail: ... [email protected] or [email protected] Web site ...www.zonare.com FTP site (Service) ... ftp://12.40.200.87 Toll-free live-phone support: ... 1-877-913-9663 (5:00AM – 5:00PM, Pacific Standard Time) Tech Support FAX line ... 1-650-230-2817 Tech Support e-mail ... [email protected] Corporate web site... www.zonare.com FTP site (Tech Support Window):
URL ... ftp://12.40.200.87
Enter the following User Name and Password information:
User Name:
(call Tech Support for current login information)
Password: (call Tech Support for current login information)
Q00169 Rev D
Page 10 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
Europe
ZONARE Medical Systems GmbH Henkestrasse 91 91052 Erlangen, Germany Tech Support Phone ... (+49) 9131-974 94-0 (8:00AM – 5:00PM) Tech Support e-mail ... [email protected] Corporate web site... www.zonare.com
1.1
Purpose
This manual’s purpose is to provide information to assist service personnel in performing the service, maintenance, and repair procedures that may be required to support ZONARE’s Z.ONEUltra Diagnostic Ultrasound System product. 1.2
Product Overview
ZONARE’s Z.ONEUltra Convertible Ultrasound System provides a combination of a full-featured, cart-based ultrasound system, with the versatility of a compact, easily transportable to the patient, selfcontained portable unit. The Z.ONEUltra Convertible Ultrasound System is offered in two different models, utilizing two different configurations of Carts. The sub-systems that comprise the Z.ONEUltra product are listed below:
Full-Feature SmartCart or lightweight miniCart
Portable “Scan Engine” (or docked “Scan Module”
Ultrasound transducer(s)
The portable Scan Engine consists of a limited number of field replaceable units (FRU’s). The FRU’s for this unit are:
Lithium-Ion battery pack
USB Memory Stick
Scan Engine (complete)
The SmartCart consists of a limited number of field replaceable units (FRU’s). The FRU’s for this unit are: Q00169 Rev D
Page 11 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
19” Display Monitor
User Interface Assembly
OLED Sub-Assembly (part of UI)
Main Board Assembly
Power Supply Module
Z-PAK Battery Pack
Scanner Deck (w/MTP)
MTP Bolster Plate (or MTP w/CW)
ECG Module
Misc cables and mechanical assemblies
The miniCart consists of a limited number of field replaceable units (FRU’s). The FRU’s for this unit are:
AC Fuses
Main Power Supply (DC)
USB Hub
LCD Display
Remote Keyboard
Wheels
In addition to the two different Cart offerings, the Z.ONEUltra Ultrasound System is offered with two different configurations of scanner electronics. One version being a standalone portable use “Scan Engine” (with local LCD display and user interface controls), and the other being a “brains only” (non-portable) “Scan Module”.
Scan Engine
Scan Module
The ultrasound transducers are replaced as a single FRU, with no field-serviceable parts. 1.3
Product Features
The Z.ONEUltra ultrasound system includes the following key features:
Q00169 Rev D
Page 12 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
Full function scanning modalities (B-Scan, M-Mode, Color Flow, Power Doppler, PW Dopper)
Remote portability for patient scanning
1.4
Definitions/Acronyms 2D: ... Two dimensional (B-Mode, Color mode) BMP: ... Bit MaP C: ... Color Flow Mode (Doppler) D: ... Doppler (Pulsed Wave) Mode DICOM: ... Digital Imaging and COmmunication in Medicine DSP:... Digital Signal Processing ESD:... Electro Static Discharge EV:... Endo Vaginal FPGA: ... Field Programmable Gate Array FRU: ... Field Replaceable Unit HSSL: ... High Speed Serial Link LCD: ... Liquid Crystal Display LED: ... Light Emitting Diode M:... M-Mode (Motion Mode - Tissue) NTSC:... National Television Standards Committee (video standard) PAL: ... Phase Alternation by Line (video standard) PRF:... Pulse Repetition Frequency PW: ... Pulsed Wave Mode (Doppler) Retrospective: .. Post-processing performed on frozen images from memory SVGA: ... Super Video Graphics Array DGC: ... Depth Gain Compensation USB:... Universal Serial Bus
Q00169 Rev D
Page 13 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
VKB:... Virtual KeyBoard
Q00169 Rev D
Page 14 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
1.5
Documentation Conventions
This following alert conventions are used in this manual: 1.5.1
Alert Messages
1. A WARNING indicates that PERSONAL INJURY OR DEATH may occur to patient and/or user if the user does not observe the provided information. WARNING
2. A CAUTION indicates that DAMAGE TO EQUIPMENT may occur if the user does not observe the provided information. CAUTION
3. A PRECAUTION indicates that INCONVENIENCE TO THE USER (such as loss of text entries or saved settings) may result if the user does not observe the provided information. PRECAUTION
4. Common terms that have a special meaning for the Z.ONEUltra (e.g. Menu Control or Trackball) are capitalized to distinguish their special usage (as opposed to a person who does navigation). 5. Control and function names (e.g. Print Button, Image Display) are capitalized for recognition. 6. Items to be acted upon are underlined (e.g. press the Store Button). Items needing emphasis are in boldface type.
1.5.2
Symbols
The following symbol conventions are used in this manual, and/or on the Z.ONEUltra product: This symbol is used to draw attention to information that may relate to safety of the patient, the operator, or the equipment.
Q00169 Rev D
Page 15 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
Caution: ESD sensitive
This symbol indicates that the equipment is not Category AP, and therefore must not be used in the presence of flammable liquids or gasses.
. Type BF patient applied part (B= body, F= floating applied part).
This symbol indicates that the equipment does not utilize a floating double insulated isolation connection, and therefore must not be connected to external equipment that is not protectively earthed (DO NOT connect to class II equipment).
Storage/Operating Temperature conditions Alternating Current (AC) Direct Current (DC)
Date of manufacture
Q00169 Rev D
Page 16 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
2
SAFETY
It is extremely important to read the following definitions of WARNING information, prior to beginning any service on any sub-system within the Z.ONEUltra product. As you see applicability of each of these noted WARNINGs, during the course of the servicing process, be prepared to avoid harm to persons and equipment by proper adherence. 2.1
CAUTIONs and WARNINGs During Service/Operation
CAUTION On the miniCart, to prevent possible damage to the 13” display monitor during system transport (or moving for relocation within the facility) the monitor should first be folded down to horizontal, rotated to a center position, and “locked” into place using the provided retaining pin located on the bottom of the display arm.
CAUTION To prevent possible damage to the electronics of the system from condensation, the following warning must be observed: Anytime that any Zonare equipment (Scan Engine, SmartCart or minCart) is being moved from an environment that differs greatly in temperature and/or humidity, from the environment where it has been moved for intended operation, (as a result of shipping or transport) the unit should be allowed to stand for a period of no less than 30 minutes, prior to inserting battery or powering on.
WARNING Inspect all cables and power cords BEFORE powering-on the Z.ONEUltra system; or connecting the transducer. Do not use the system if visual signs of external damage are observed.
WARNING To achieve proper grounding reliability, the Z.ONEUltra SmartCart or miniCart power plug must be fully inserted into a receptacle marked 'Hospital Grade". Do not remove the grounding wire. If there is any question of power outlet or power cord integrity, do not proceed. Obtain qualified technical assistance.
WARNING The ZONARE Z.ONEUltra contains no operator-serviceable components within the enclosures. To avoid electrical shock, the no covers should be removed except by ZONARE factory trained personnel. Failure to do so may void the system warranty or service contract coverage Warnings.
Q00169 Rev D
Page 17 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
WARNING Do not operate the Z.ONEUltra system in the presence of flammable anesthetics or in a room recently washed with flammable cleaning and disinfecting agents. Cleaners can produce explosive vapors. Check labels of original containers of cleaners and disinfectants for warnings about vapors. Thoroughly ventilate the room, if such vapors may potentially be present, prior to activating any of the Z.ONEUltra components.
2.2
Battery WARNINGs
WARNINGS.
2.3
The battery has a safe smart device. Do not disassemble or alter the battery in any way.
Charge the battery at room temperature.
Do not short-circuit battery by directly connecting the positive and negative terminals with metal objects.
Do not heat or discard battery in a fire.
Do not expose the battery to temperatures above 150 degree F.
Do not charge the battery near a heat source
Do not leave battery in direct sunlight
Recharge battery only using Scan Engine in a docked condition in Z.ONEUltra SuperCar or miniCartt, or remotely using ZONARE Z.ONE battery charger.
Do not use a damaged battery.
Inspect the battery for damage before charging or placing the battery in the Z.ONEUltra.
Do not connect battery to an electrical power outlet.
Do not continue to recharge the battery if it does not recharge fully after 4 hours
Battery MUST be REMOVED from Scan Engine, during shipping/transport Z.ONEUltra
of the
CAUTIONs During Service
CAUTIONS
Apply proper line voltage. Verify that the Z.ONEUltra system is compatible to match the AC voltage of site receptacle. Also verify that all plugs match the receptacle type. Mismatched voltage or plug configuration can damage system components.
Protect the system from water or other liquids that could drip into the electronic components. Do not drop the transducer(s), or allow them to impact any hard surfaces.
Q00169 Rev D
Page 18 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
Avoid allowing metal contact pins on connector-end of transducers to come in contact with foreign surfaces (potential for bending pins). Perform no unauthorized modification to any of the Z.ONEUltra sub-systems. Unauthorized modification can introduce additional hazards to the product.
2.4
Battery CAUTIONs
CAUTIONS To protect the battery from potential thermal damage, the system monitors the temperature of the battery at all times. If the battery is detected as exceeding the maximum safe operating temperature, a warning message will appear on the display of the Z.ONEUltra. To prevent possible damage to the unit, the battery should be REMOVED from the Scan Engine prior to transport or shipment. Do not immerse battery in water or allow it to get wet. Do not put the battery into a microwave oven or pressurized container. Use only batteries provided by ZONARE Store the battery between -20 to 60o Celsius (-4 o to 158 o F). If the battery leaks, emits orders, emits heat, is deformed or discolored in any way immediately remove it and stop using it.
2.5
USB Memory Stick CAUTIONs
CAUTIONS USB Memory Sticks that are purchased from outside sources (besides Zonare) may not be compatible for use in the Z.ONEUltra. USB Memory Sticks which are labeled as “U3 Smart Technology” on their label or packaging, will NOT be recognized (or function) in the Z.ONEUltra. In the case of having one of these incompatible format USB Memory Sticks. There are freeware U3 Smart Technology “Removal” programs available on the internet, that can be downloaded and run to make the USB Memory Sticks useable on the Z.ONEUltra
2.6
Networking CAUTION
CAUTIONS In order to comply with Electro-Magnetic Compliance it is necessary that the Z.ONEUltra be connected to available Ethernet resources using a high quality, shielded CAT-5 cable.
Q00169 Rev D
Page 19 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
3
SYSTEM SPECIFICATIONS
This section contains Z.ONEUltra system and accessory specifications. For information on the specifications for ZONARE authorized peripherals, refer to the manufacturers’ documentation. 3.1
System Dimensions
SmartCart (with Scan Engine installed)
Height: - Max operational: 157.5 cm (62 in) - Min operational: 128 cm (50.5 in) - Display lowered for transport: 104 cm (41 in)
Width: 51 cm (20.1 in) Depth: 72 cm (28.2 in) Weight: 57 kg (125lb.)
miniCart (with Scan Engine installed)
Height: - Max operational: 160 cm (63 in) - Min operational: 134 cm (53 in) - Display lowered for transport: 104 cm (41.5 in.)
Width: 57.2 cm (22.5 in) Depth: 56.1 cm (22.0 in) Weight: 55 kg (132 lbs.)
Scan Engine
Height: 7.3 cm (2.9 in) Width: 18.7 cm (7.4 in) Depth: 25 cm (9.8 in) Weight: 2.5 kg (5.6 lb) – with battery, no probe
Scan Module
Height: 5.3 cm (2.1 in) Width: 22.3 cm (8.8 in) Depth: 25 cm (10.0 in) Weight: 1.6 kg (3.5 lb)
Q00169 Rev D
Page 20 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"
3.2
Displays
SmartCart
19” high resolution color LCD display 1280 x 1024 display format (internal) 1280 x 1024 / 800 x 600 video format - configurable (HDMI output) 0.41 mm pixel pitch Viewing angle (H/V): 170 degrees typical Minimum 10:1 contrast +/- 90o rotation 30o backward tilt Full 90o forward tilt into secure transport position Advanced setup parameters via on-screen menu Integrated system programmed video settings Multi-Transducer Port (3 Connectors) - Option
miniCart
13” high resolution color LCD display 640x480 display format (internal) 0.41 mm pixel pitch Viewing angle (H/V): 170 degrees typical Minimum 10:1 contrast +/- 90o rotation 30o backward tilt Full 90o forward tilt into secure transport position Integrated system programmed video settings
Scan Engine
5.8” high resolution color LCD display 800x480 display format (internal) 640x480 video format (HDMI output port) 0.16 mm pitch Manual Brightness and Contrast controls USB 2.0 I/O port (one) DC power (+12V) input port
Scan Module
640x480 video format (HDMI port) USB 2.0 port (one)
Q00169 Rev D
Page 21 of 304 "Note: Copies are uncontrolled documents - For revision verification see the Master Documentation List"