AESCULAP® AdTec® BIPOLAR DISASSEMBLY | ASSEMBLY INSTRUCTIONS DISASSEMBLY  y Disconnect shaft and handle Pull the rotation knob back and hold it in this position.  y Remove shaft from handle  y Disassemble handle  Hold the jaw insert firmly by its protecting cap and pull it out of the handle. Important: Do not hold on to the movable handle component.  Pull the grey rotation knob forwards off the handle.  y Disassemble shaft I  y Disassemble shaft II  Hold the jaw insert at the protecting cap and remove the outer insulation tube.  Hold the jaw insert at the protecting cap and remove the inner metal tube.  ASSEMBLY  y Assemble shaft I Slide the metal inner tube onto the jaw insert with its four spring tongues towards the working end until the tongues snap in place.  y Assemble shaft II  y Prepare handle  Slide the outer insulation tube as far as it will go over the inner metal tube.  CARE  Push the grey rotation knob onto the handle from the front. Bring the movable handle component into its forward position.  PROCESSING & ACCESSORIES  y Function test  Pull the rotation knob back and hold it. Hold the shaft firmly by its protecting cap and push it into the handle. Release the rotation knob, which moves forward. Important: Do not hold on to the movable handle component.  Reprocess the product immediately after use  outer insulation tube  y  The product can be sterilized either in disassembled or in assembled condition  inner metal tube  For advice on cleaning, disinfection and sterilization, please follow the instructions for use. For effective cleaning, particularly of the jaws, we recommend B. Braun Stabimed®.  y  For the latest information on reprocessing, please also refer to the Aesculap Extranet via www.aesculap-extra.net  y  For accessories and spare parts, please refer to Brochure C75802 or visit www.endoscopy-catalog.com  Test the assembly of the instrument by opening and closing the handle to ensure the jaw is opening and closing.  REPAIRS  y  y  y Lubricate the defined places on the instruments with AESCULAP® STERILIT® Oil after each cleaning cycle.  y Connect shaft and handle  2  jaw insert  3  1 protecting cap 2 rotation knob 3 movable handle component  1  y In order to ensure the preservation of full guarantee and warranty rights, only persons authorized by Aesculap may carry out repairs. Please send articles for repair to: Aesculap Technical Service, Am Aesculap-Platz, D-78532 Tuttlingen, Germany. Additional service addresses may be obtained from the same address or via ats@aesculap.de C22302  AESCULAP ® – a B. Braun brand The main product trademark “Aesculap” and the product trademarks “AdTec” and “Sterilit“ are registered trademarks of Aesculap AG. Subject to technical changes. All rights reserved. This brochure may only be used for the exclusive purpose of obtaining information about our products. Reproduction in any form partial or otherwise is not permitted.  Aesculap AG | Am Aesculap-Platz | 78532 Tuttlingen | Germany Phone +49 7461 95-0 | Fax +49 7461 95-2600 | www.aesculap.com  0721/PDF/3
File Type: PDF
File Size: 353 KB
File Name: Aesculap - ADTEC BIPOLAR - C22302 - AdTec BIPOLAR Disassembly - Assembly Instructions - 2021-07.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions