MyoSure Instrument Tray

MyoSure Instrument Tray Instructions for Use

2 Pages

ENGLISH  Instrument Tray Instructions for Use Indications for Use/Intended Use  •  The MyoSure® Instrument Tray is intended to enclose, protect, and organize the MyoSure® Rod Lens Hysteroscope, MyoSure® Removable Outflow Channel, and associated components, during sterilization and storage.  •  Hologic recommends the use of a mild enzymatic detergent with a near neutral pH. Do not use solvents, abrasive cleaners, metal brushes, or abrasive pads. Trays may be placed in mechanical cleaning equipment  The MyoSure® Instrument Tray must be used in conjunction with a sterilization wrap that is cleared by FDA for the indicated sterilization cycle, and may be stored for up to 30 days in accordance with the wrap manufacturer’s instructions.  •  The MyoSure® Instrument Tray has been validated for the following sterilization cycles:  CAUTION: Trays are reusable but may eventually be damaged. Always inspect tray components for cracking, chipping, or other signs of damage before use. Make sure all latches and handles are secure and in working order. Damaged trays should be removed from service. Minor Surface cosmetic changes may occur with long-term use or after Sterrad® processing.  Prevacuum Steam  Gravity Steam  STERRAD® 100S™  132°C (270°F)  132 °C (270 °F)  59% H2O2  4 minutes exposure  15 minutes exposure Normal Cycle Setting Normal Cycle Setting  30 minutes dry time  30 minutes dry time  Contents - 1 MyoSure® Rod Lens Hysteroscope, 1 Removable Outflow Channel, 2 Seal Caps, 2 Light Guides  Contents - 1 MyoSure® Rod Lens Hysteroscope, 1 Removable Outflow Channel, 2 Seal Caps, 2 Light Guides  CAUTION: Always inspect tray components for cleanliness and confirm that there is no visual contamination prior to use.  CAUTION: Only use accessory components that have been designed and tested for use in MyoSure® Instrument Trays.  Contents - 1 MyoSure® Rod Lens Hysteroscope, 1 Removable Outflow Channel, 2 Seal Caps, 2 Light Guides  Sterilization Recommendations Do not overload trays. Place and arrange tray contents in accordance with Figure 1 to facilitate sterilant contact with all objects in the tray.  Contraindications Stacking of trays and overloading of the units will adversely affect sterilization and drying effectiveness. DO NOT STACK trays in the sterilization chamber.  Care and Cleaning Recommendations • • • • • •  Pre-Rinse soiled trays in tap water for 2 minutes Both physical and chemical (enzymatic detergent) processes may be necessary to clean soiled items. Follow enzymatic detergent manufacturer’s instructions Chemical (enzymatic detergent) cleaners alone may not remove all soil and debris; therefore, a careful manual cleaning of each item with a soft sponge or cloth is essential. For difficult access areas, a clean, soft-bristled brush is recommended. Repeat cleaning steps if visible contamination of tray components is observed. Once the items have been cleaned, they should be thoroughly rinsed with clean water to remove any detergent or chemical residue before sterilization. 1  Figure 1  Process the tray according to the sterilization wrap manufacturer’s instructions prior to sterilization to maintain sterility of internal components/items and for proper aseptic presentation to the surgical field. Product may be maintianed for up to 30 days after sterilization in accordance withthe wrap manufacturer’s intructions.  Steam Sterilization Performance of the MyoSure® Instrument Tray has been verified in the following steam autoclave cycles for sterilization of the MyoSure® Rod Lens Hysteroscope and accessory components.
File Type: PDF
File Size: 225 KB
File Name: HOLOGIC - MAN-02848-001 - MyoSure Instrument Tray Instructions for Use - 2013-02 - Rev 002.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions