Distal Cover

How to use the single use distal cover For EVIS EXERA III Duodenovideoscope

2 Pages

How to use the single use distal cover  MAJ-2315 for EVIS EXERA III Duodenovideoscope TJF-Q190V WARNING This quick reference guide is a summary of the steps necessary to properly use your MAJ-2315. Follow the detailed steps  instructed in the latest OPERATION/REPROCESSING MANUAL for TJF-Q190V.  CAUTION Do not apply anti-fogging products, olive oil, or products containing petroleum-based substances (e.g. Vaseline®) to the  distal cover and the endoscope. These products may cause cracks of the distal cover. If a distal cover with cracks is used, it may cause thermal injury due to electric current leaks when high-frequency cauterization treatment is performed.  Attaching the distal cover  1  Instrument channel outlet  Confirm not slipping and coming off.  Distal cover Distal part of the bending section  The instrument channel outlet of the distal end is opened. (the elevator control lever is in the opposite direction of the "U" direction)  3 4  Pull  Twist  3. Hold the distal part of the bending section. Pull the distal  cover gently to confirm that it does not slip and come off.  1. Gently hold the distal part of the bending section and the distal cover. Align the opening side of the distal cover with the lens side of the distal end of the endoscope.  2  4. Twist the distal cover gently in both directions and confirm  that the distal cover on the distal end of the endoscope does not slip and come off.  5  6  7  Push  Distal cover Centre of the top Hook  Distal cover  2. Put your finger onto the centre on the top of the distal cover and push the top of the distal cover straight onto the distal end of the endoscope until the hook of the distal ring is completely visible within the opening of the distal cover.  Reason:The hook of the distal ring is not completely visible within the opening of the distal cover  5. Confirm that the distal cover is free of cracks or deformation. 6. Confirm that there is no adhesion of foreign materials  between the distal end of the endoscope and the distal cover.  7. Confirm that the single use distal cover is not seen on the endoscopic image.  Reason:The single use distal cover is partly on the endoscopic view
File Type: PDF
File Size: 3.52 MB
File Name: OLYMPUS - QR 07.307 - How to use the single use distal cover For EVIS EXERA III Duodenovideoscope - 2019-11 - V 1.0.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions