ENDOEYE FLEX 10 HD VIDEOSCOPE

ENDOEYE FLEX video laparoscope, Preventing Potential Damage

2 Pages

ENDOEYE FLEX video laparoscope  PREVENTING POTENTIAL DAMAGE DAMAGE DURING AN OPERATION Tear caused by trocar’s distal end  Tear or puncture caused by instrument Grasper  NO  YES  Damage can be caused by not straightening the distal end of the laparoscope prior to withdrawal from the trocar.  When introducing the laparoscope, always use the included trocar introducer (only for LTF-VP, LTF-VP-S and LTF-S190-5). Before withdrawing the laparoscope from the trocar, be sure to release the angulation release lever and straighten the bending section.  Tear caused by grasper  NO  YES  An instrument such as scissors or a grasper may come into contact with or grasp the bending section and damage the cover sheath.  When using laparoscopic instrumentation, observe the laparoscopic image closely to make sure that the scope and laparoscopic instrument are correctly positioned relative to one another.  Tear caused by surgical needle  NO Grasping the bending section to adjust the position of the scope.  Scissors  NO  YES  A sharp device such as a surgical needle may come into contact with the bending section and damage the cover sheath.  When inserting or withdrawing a sharp device such as a surgical needle, be careful not to catch the needle tip in the bending section cover sheath.  YES Do not grasp the bending section with the grasper, etc. Always use the positioning lever.  Tear caused by ultrasonic coagulation/cutting scissors  NO  YES  The ultrasonic instrument may come into contact with the bending section during output mode.  Do not grasp the bending section. Check the laparoscopic image during output so that the probe does not come into contact with the laparoscope’s bending section.  INTRA-OPERATIVE HAZARDS Slack, sag, or rollup of bending section cover sheath Slacking of cover sheath can cause an increase in the external diameter at the localized area.  Reduction in the angulation of the bending section Insufficient angulation of the bending section.  NO  NO  The bending section was withdrawn from the trocar without straightening, resulting in damage to the bending section.  The laparoscope was inserted into the trocar with a valve that was not open.  YES • Turn the angulation lock to the free position and maneuver the bending section until it is straight. • Carefully withdraw the laparoscope while observing the laparoscopic image. • When using a trocar with a valve, keep the valve open during withdrawal. • Never use the laparoscope when its cover sheath is turned over. • When using a trocar introducer with a valve, keep the valve open while inserting or withdrawing the laparoscope. Neglecting to do so may damage the bending section of the laparoscope.  NO  YES  Angulation was attempted while the bending section was inside the trocar.  Be sure that the bending section is completely inserted through the trocar before performing angulation. Insertion Length Index indicates how far the insertion section is inserted into the trocar tube. Insertion Length Index
File Type: PDF
File Size: 3.51 MB
File Name: OLYMPUS - P0097EO - ENDOEYE FLEX video laparoscope, Preventing Potential Damage - 2011-10 - Not Listed.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions