Linear EUS Scope

ENDOSCOPE CLEANING GUIDE

1 Page

ENDOSCOPE CLEANING GUIDE GF-UCT180 Linear EUS Scope  Refer to companion ENDOSCOPE DISINFECTION GUIDE for disinfection information  WARNING:This guide is only a summary of the steps necessary to properly clean your endoscope. Be sure to follow the  detailed steps outlined in the INSTRUCTION MANUAL  LEAKAGE TESTING 1  that was included with your endoscope purchase.  MANUAL CLEANING 2  If a leak is detected, the endoscope must be repaired. Follow the manufacturer's instructions.  While immersed:  3  4  Brush the groove of the interior of the forceps elevator (left).  Attach leakage tester. Turn on pump. Immerse endoscope in clean water. Perform leakage test (angulate tip). Remove from water. Detach tester from the air source. After the tip has deflated, detach the tester from the water-resistant cap.  While immersed:  5  Immers e in fres hly prepared detergent solution. Clean all external surfaces. Brush endoscope distal tip (and forceps-elevator, as follows).  While immersed:  7  6  Ensure elevator is lowered. While holding the distal end, brush the groove of the interior of the forceps elevator (middle) of the instrument channel opening from the distal end with the MAJ-1534 Cleaning Brush until all debris is removed.  Brush the groove of the interior of the forceps elevator (right).  While immersed:  8  9  While immersed:  Brush  A  Brush the groove of the interior of the forceps elevator (left).  Raise the forceps elevator. While holding the distal end, brush both sides (left and right; see step 6) of the forceps elevator and the opposite side of the groove (back) of the forceps elevator with the MAJ-1534 Cleaning Brush until all debris is removed.  Brush the groove of the interior of the forceps elevator (right).  While immersed:  10  Brush the distal end of the endoscope, using the MAJ-1534 Cleaning Brush. Raise and lower the forceps elevator 3 times.  11  While immersed:  12  While immersed:  Suction Valve  13 Brush  Brush  B  With the forceps elevator raised, flush behind the forceps elevator with detergent solution using a 30 ml syringe.  Brush the balloon channel. Repeat until all debris is removed.  14  Suction Cleaning Adaptor  Injection Tube & Channel Plug (or All-Channel Irrigator)  Distal tip  C  Brush the univers a l cord portion of the suction channel. Repeat until all debris is removed.  Brush the ins ertion tube portion of the suction channel. Repeat until all debris is removed.  Brush the suction cylinder and instrument channel port. Repeat until all debris is removed.  Attach suction valve. Aspirate detergent, then air into suction and balloon channels.  Attach injection tube & channel plug. Flush 150mls of detergent solution into air, water, and balloon channels. Detach the injection tube and channel plug, and leave them immersed.  RINSING 15  Washing Tube  16  17  18  Injection Tube & Channel Plug  5cc Syringe  30cc Syringe  5cc Syringe Washing Tube  Flush 15mls of detergent solution into elevator-wire channel, using the washing tube. Disconnect the washing tube from the endoscope and immerse in detergent solution.  Wipe down endoscope with a lint-free cloth. Soak in detergent solution for the time recommended by the detergent manufacturer.  R ins e the entire ins trument in clean water.  CAUTION 19  Do not hit the distal end of the endoscope against hard surfaces.  Flus h clea n wa ter through a ll cha nnels (including elevator-wire channel). Flush air through all channels.  IMPORTANT • Wear all appropriate personal protective equipment.  • Meticulous cleaning is essential for effective disinfection.  • Be sure to reprocess all  removable parts (e.g. valves) according to the instruction manual.  Use a soft, lint-free cloth to remove excess moisture from the endoscope and cleaning accessories in preparation for disinfection.  Do not forget to attach waterresistant caps.  • Visually inspect the equipment after cleaning. If debris remains, repeat the procedure.  • MAJ-1534 Cleaning Brush is autoclavable.  For complete product details see Instructions for Use.  OLYMPUS AU STRALIA PTY LTD 3 Acacia Place, Notting Hill VIC 3168, Australia Customer Service: 1300 132 992 | www.olympusaustralia.com.au  OLYMPUS NEW ZEALAND LIMITED 28 Corinthian Drive, Albany, Auckland NZ 0632 Customer Service: 0508 659 6787 | www.olympus.co.nz QR 07.303 V1.0 November 2019
File Type: PDF
File Size: 6.13 MB
File Name: OLYMPUS - QR 07.303 - ENDOSCOPE CLEANING GUIDE - 2019-11 - V1.0.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions