BENDING PLIERS FOR RECONSTRUCTION PLATES 10"

Pilling Metal Reusable Complex Design Instruments Cleaning , Disinfection and Drying Instructions

14 Pages

en  INSTRUMENT DESCRIPTION The following instructions are for metal reusable complex design instruments that are characterized by the following design features: a. Non-accessible surfaces (requires manipulation to gain access) b. Blind holes c. Non-accessible apertures d. Adjustable spring tension e. Cannot be disassembled to simpler components or sub-assemblies •  Lowman Bone Clamp  •  10" Heavy-duty locking pliers  For additional information or guidance on Cleaning and Sterilization instructions, contact your Teleflex Sales Representative or Teleflex Customer Service.  INDICATIONS FOR USE Teleflex instruments are designed to perform a specific function, such as cutting, grasping, clamping, dissecting, probing, retracting, draining, aspirating and suturing. Instruments are for use by, or as directed by, a trained medical professional. Instruments should be used only for the purpose for which they are designed. The proper technique for the use of the instrument is the responsibility of the medical professional. PREPARATION AT POINT OF USE Directly after use, remove coarse contamination from the instrument and keep the instrument moist for transit to the processing site. Prior to cleaning and sterilization do not use any fixing agents or hot water >104°F (>40°C) since this may lead to the fixation of residue and can interfere with the cleaning process.  TRANSPORTATION During the transportation of the instrument to the processing site, store contaminated instrument securely in a closed container to avoid damage to the instrument and/or contamination of the environment. PREPARATION FOR REPROCESSING Where applicable, instruments must be disassembled and/or opened for cleaning and sterilization. Open ring handled instruments so that ratchets are not engaged. Failure to properly clean and sterilize the instrument could lead to contaminated instruments being placed back into circulation.  CLEANING, DISINFECTION AND DRYING INSTRUCTIONS Automatic Processing Instructions Manual Processing Instructions For Use with Alkaline or Enzymatic For Use with Enzymatic Detergents Detergents PRE-CLEANING • Soak the instrument in lukewarm tap water for a minimum time of 5 minutes. • Brush the instrument under lukewarm tap water until all visible contamination is removed. • Rinse the instrument, particularly lumen, luer-loks, hinges, gaps and cavities with a water jet pistol (pressure gun, static pressure greater than 4 bar) for 10 seconds. • Soak the instrument in an ultrasonic bath for 10 minutes at (104°F) 40°C with 0.8% solution of enzymatic cleaner (See Note below). • Rinse the instrument, particularly lumen, luer-loks, hinges, gaps and cavities with a water jet pistol (pressure gun, static pressure greater than 4 bar). CLEANING Automatic Cleaning (Enzymatic) • Place the opened instruments in a wire basket on the slide-in tray and start the cleaning process. • Pre-rinse for 1 minute with cold water. • Empty. • Pre-rinse for 3 minutes with cold water. • Empty. • Wash for 5 minutes at 113°F (45°C) with a 0.8% enzymatic detergent. • Empty. • Neutralize for 3 minutes with cold water. • Empty. • Rinse for 2 minutes with cold water. • Empty. Automatic Cleaning (Alkaline) • Place the opened instruments in a wire basket on the slide-in tray and start the cleaning process. • Pre-rinse for 1 minute with cold water. • Empty. • Pre-rinse for 3 minutes with cold water. • Empty. • Wash for 5 minutes at 131°F (55°C) with a 0.5% alkaline detergent. • Empty. • Neutralize for 3 minutes with cold water. • Empty. • Rinse for 2 minutes with cold water. • Empty. Note: The concentration, temperature and application time of the cleaning agent must be according to the instructions for use of the manufacturer. Examples of detergents used in validation studies: Enzymatic Detergent: Cidezyme/Enzol; Alkaline Detergent: Neodisher Mediclean.  • Automatic cleaning only.  CLEANING • Manual cleaning not recommended. Automatic cleaning only.
File Type: PDF
File Size: 1.2 MB
File Name: Teleflex Medical - Pilling - L05506 - Pilling Metal Reusable Complex Design Instruments Cleaning, Disinfection and Drying Instructions - 2020-04 - R02.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions