INSTRUCTIONS for USE and REPROCESSING Indication: All surgical instruments comprising fixed assemblies, simple hinged surgical instruments, and simple assemblies, including those containing stainless steel, titanium and aluminium. Non-sterile device. Federal U.S. laws restrict this device to sale, distribution, and use, by, or on the order of a physician. WARNING: Single Use Devices are to be sterilized and used only once. WARNING: If this device is/was used in a patient with, or suspected of having Creutzfeldt-Jakob Disease (CJD), the device cannot be reused and must be destroyed due to the inability to reprocess or sterilize to eliminate the risk of cross-contamination!  Cleaning preparation before use Warning - Risk of infection! Before the initial use and before every further usage, the entire device, including its accessories must be decontaminated. An inadequate, incorrect, or superficial decontamination can create a serious risk of infection in patients and/or the user. Warning: Any variation between what is suggested here and your facility’s policies and procedures or those indicated by your sterilizer manufacturer should be brought to the attention of the appropriate responsible persons at your facility for direction before cleaning and sterilizing your instruments. Prior to use, all instruments should be inspected to insure proper function and condition. Do not use instruments if they do not perform satisfactorily. Fading of color-anodized aluminium instruments may be accelerated if cleaning and sterilization recommendations below are not followed. Remove all protecting caps and sheats carefully. Before beginning to use the instrument, the instrument must be cleaned, lubricated, decontaminated, sterilized and inspected before use in surgery. For all Lowsley Prostatic Retractors, inject cleaning fluid through the flush port, which allows the cleaning fluid to pass freely along the walls of the lumen and base/end. Cleaning fluid exits at the distal tip of the device. The lumen chamber at the base is flared to enhance the flow of solution. Ultrasonic cleaning of this device is not recommended. Limitations on reprocessing Repeated processing has minimal effect on these instruments. End of life is normally determined by wear and damage due to use. Attention: Risk of damage – The surgical instrument is a precision device. Careful handling is important for the accurate functioning of the product. Improper external handling (e.g. bending, banging, dropping, etc.) can cause product malfunction.  INS_LBL-00066 REV. B Page 1 of 4
File Type: PDF
File Size: 67.4 KB
File Name: Teleflex Medical - Pilling - L06059 - Pilling Surgical Instruments Instructions for Use and Reprocessing - 2020-04 - Rev B.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions