Thompson

Latch Cam Joint ½" x ½"

Retractor Systems Instructions for Use

2 Pages

Thompson Retractor  IMPORTANT INFORMATION FOR USE OF THOMPSON RETRACTOR SYSTEMS AND INSTRUMENT CASES  (NOT including illumination products, silicone sleeve, or discontinued Adjustable Height Rail Clamp. Please note, this does include the Infinite Height Rail Clamp.): This IFU is intended to assist health care personnel in safe handling practices, effective reprocessing, and maintenance of all Thompson Surgical Instruments, Inc.’s retractor systems and accessory families. End of usable life for metal surgical instruments is normally determined by wear and damage due to intended surgical use. All Thompson Retractor products and accessories are latex-free. EC  Thompson Surgical Instruments, Inc. 10341 East Cherry Bend Road Traverse City, Michigan 49684 *Indicate (RMA #) on return shipments*  Rev L 052918 dc trifu  phone: fax:  (800) 227-7543 (IN USA) +1 (231) 922-0177 (OUTSIDE USA) +1 (231) 922-0174  0297  REP  Emergo Europe Prinsessegracht 20 2514 AP The Hague THE NETHERLANDS  IMPORTANT INFORMATION FOR USE OF THOMPSON RETRACTOR SYSTEMS AND INSTRUMENT CASES  ENGLISH PLEASE READ BEFORE USE  Failure to follow these instructions may render device unusable and may void warranty or service agreements. DESCRIPTION: The Thompson Retractor is a reusable device designed to provide access and exposure for a variety of surgical procedures. The Thompson Retractor is designed with interchangeable frame components, accessories, and blades to meet a variety of patient anatomies and procedures. SCOPE: This IFU provides recommended information for the cleaning and sterilization of reusable surgical retractor systems and accessories* that are manufactured and/or distributed by Thompson Surgical Instruments, Inc. Always reference our website, www.thompsonsurgical.com, for the most current revision of this IFU. *Accessories refer to our retractor system components such as adapters, wrenches, instrument cases, etc. This does NOT refer to our illumination products, silicone sleeve, or Adjustable Height Rail Clamp. INTENDED USE: The Thompson Retractor is intended for use during surgical procedures in order to provide surgical access and exposure. Thompson Surgical retractor systems and accessories are supplied non-sterile. This IFU is intended to assist health care personnel in safe use and handling practices, effective reprocessing, and maintenance of all Thompson Surgical Instruments, Inc.’s retractor systems and accessory families. All instruments must be inspected, cleaned, and sterilized prior to each use. CONTRAINDICATIONS: None known LIMITATIONS ON REPROCESSING: Repeat processing, according to the instructions in this IFU, has minimal effect on instrument life. Any limitations to reprocessing cycles will be noted in this IFU. WARNINGS AND PRECAUTIONS: PPE (Personal Protective Equipment): Should be worn, per individual hospital protocol, when handling or working with contaminated (or potentially contaminated) instruments. CJD (Creutzfeldt-Jakob Disease): Discard or destroy instruments in contact or exposed to patients with CJD, or those suspected of CJD. (Thompson Surgical does not advocate nor provide any validated instructions to eliminate risk of cross-contamination.) 1. Medical professionals should be familiar with all product support literature and videos to perform procedures with this device before use. 2. Many variables such as patient anatomy, pathology, and surgical techniques may influence the procedure’s outcome. Patient, product, and procedure selection is the responsibility of the medical professional. 3. Do not over-retract. Only use as much retraction as necessary to provide adequate exposure and access. 4. Relax the retractor periodically to ensure proper blood flow. 5. Avoid compressing the patient’s body with frame components to prevent nerve damage. See user manuals for proper setups and components to meet various patient anatomies. 6. Table mounted frame prevents most retractors from moving relative to patient movement. Use caution when moving patient while retractor is in use. 7. Do not move, retract, or adjust blades or frame components when blades are fixed to the spine with pins. 8. If using pins with blades, ensure pin distal end and thread is always engaged in spine to prevent unexpected sharps. Blade pins are not intended for distraction. 9. Products are provided non sterile and must be cleaned and sterilized before each use. 10. Normal repeated use has little effect on these instruments. Determine end of life by wear and damage due to use. 11. Product should be inspected before each use according to this IFU. Do not use products that show signs of damage such as cracking, deformation, or sharp edges. 12. Check stability of OR table rails or rail adapters/accessories before table mounting the Thompson Retractor. Only table mount to secure, non-movable rails and do not use if movement is evident. 13. Thompson Retractor products are only for use with other Thompson Retractor products unless otherwise specified by the manufacturer, such as through the offering of competitor adapter handles and other products.  14. Use of the Thompson Retractor for any purpose other than what is described here and in associated device user manuals, may cause damage or failure of the device which could result in serious patient injury or death. 15. US Federal Law restricts this device to sale to or on the order of a physician. 16. Retractor blades may compress nerves. User must evaluate the need to use free running EMG to monitor events such as retractor nerve compression outside of the visual field. DO’S AND DON’TS DO’S Use only soft, nylon brushes Use neutral (7) or low pH chemicals Use water-soluble instrument lube before each sterilization Pre-clean instruments before sterilizing Dry instruments prior to storing Protect instruments when storing Inspect instruments for damage Use distilled water when soaking instruments  DON’TS Use metal or abrasive brushes / pads Use high pH (>9) chemicals Use silicone lube or mineral oil Sterilize without first pre-cleaning Store instruments wet or semi-dry Store instruments unprotected / piled Use damaged / suspect instruments Use saline when soaking instruments  SYMBOL LEGEND: EC  Manufacturer  REP  EC Rep  0297 CE Mark  Warnings / Precautions  Biological Risks  DO NOT Reuse  Non-Sterile  Keep Dry / Protect from Moisture  DO NOT USE if Package Damaged / Compromised  Continued on back...
File Type: PDF
File Size: 221 KB
File Name: Thompson - 052918 dc trifu - Retractor Systems Instructions for Use - 2018-05 - Rev L.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions