Toby Orthopaedics

TOBY Plate System

WOLF Lone Bone Plate System Cleaning and Sterilization Instructions

3 Pages

WOLF® Cleaning and Sterilization Instructions Toby Orthopaedics, Inc. 401 SW 42  nd  Ave, Suite 200  Miami, Florida 33134 USA Domestic Toll-free: 866.979.TOBY (8629) Office: 406.556.3260 Email: sales@TobyOrtho.com Atlantico Systems LTD 34 Oldfield Kingston Galway Ireland Phone: +35 391443609 Product  WOLF® Long Bone Plate System  Warnings  1. 2. 3. 4. 5.  Reprocessing Limitations  1. 2.  Intended Use  1. 2. 3.  Point of Use  1. 2. 3.  Containment / Transportation  1. 2.  Preparation for Decontamination  Implantable devices (plates, screws, etc.) are single use only. Reusable instruments that are provided clean and ready to use are non-sterile unless the packaging indicates otherwise. Clean and sterilize prior to each use, unless device is already provided in clean / sterile packaging. Where applicable, disassemble instruments prior to cleaning. For additional warnings, reference the WOLF® Instructions For Use (Doc 60000024). Implantable devices are single use only and may not be reused once in contact with bodily fluid, soft tissue, bone, or other sources of contamination. Repeated processing has minimal effect on reusable WOLF® surgical instruments. End of life is normally determined by wear and damage due to the use of the instruments. The WOLF® Plate system is indicated for fractures, osteotomies, and non-unions of upper extremity diaphyses. The plates and screws contained within the system are single use devices, which are designed for implantation per the relevant surgical procedure. The drill bits, drill guides, depth gauges, k-wire, drivers, and other instrumentation are designed for use during the surgical procedure and require decontamination and cleaning prior to reuse. The instruments typically contact blood, bone, tissue and bodily fluids during normal use, and therefore, require that the cleaning and processing steps are completed for each usage. Remove gross soiling by submerging the instrument into cold water (<40ºC) immediately after use. Don't use a fixating detergent or hot water (>40ºC) as this can cause the fixation of residue, which may influence the result of the reprocessing process. Remove surface contamination with paper tissue. Hospital precautions for the handling of contaminated/bio-hazardous materials should be followed. Instruments should be cleaned within 30 minutes after use to minimize the potential of staining, damage, and drying.  If possible, the devices must be reprocessed in a disassembled or opened state. 1.  Disassemble the Depth Gauge to clean each component of the assembly: Depth Gauge Slide and Housing. a. Fully retract the Slide in the Housing. b. Fully separate the Slide from the Housing while taking care to not bend the Tip.  ®  TOBY ORTHOPAEDICS 50000133-03 Page 1 of 3
File Type: PDF
File Size: 220 KB
File Name: Toby Orthopaedics - 50000133-03 - WOLF Lone Bone Plate System Cleaning and Sterilization Instructions.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions